5
VENTING
This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. This model can be
A minimum six inch diameter (6"ø)
HIGH LIMIT SWITCH
This thermally activated switch, located in front of the draft hood, senses an increase in temperature and acts as a safety
screws. In cold climates, the use of a
VENT SAFETY SWITCH
This thermally activated switch, located in front of the draft hood, senses an increase in temperature and acts as a safety
VENT SAFETY
SWITCH
THERMOSTAT OR
WALL SWITCH
FIGURE 3
HIGH LIMIT
SWITCH
VALVE |
or has no "draw", the safety switch will automatically shut off the supply of gas to the main burner within 10 minutes.
This switch must be manually reset by depress- ing the plunger. Refer to Figure 2.
Tampering with the safety switch can result in carbon monoxide poisoning and possible death.
VENTING ACTION CHECK
A test for correct venting action must be made before the installed unit can be left with the customer.
Follow the procedure below:
1.Close all doors and windows in the room / start ex- haust fans in the home / turn the fireplace blower off (if so equipped).
2.Set controls to "high" and light the unit.
3.Wait 5 minutes. Light a match and hold to the front of the draft hood. FIGURES 4 & 5.
PLUNGER |
|
A | HI LIMIT |
| |
| SWITCH |
B |
|
1 |
|
2 |
|
3 |
|
FIGURE 2 |
|
FIGURE 4
Venting action is satisfactory, if smoke and flames are drawn into the draft hood.
FIGURE 5
Venting action is unsatisfactory, if the smoke spills back, and the flame splays outward. If venting action is unsatisfactory, turn off the unit, wait 10 minutes and try again. If the smoke is still not drawn into the draft hood, turn the unit off and check for vent blockage or restriction. If necessary, consult with a quali- fied inspector.
The Vent Safety or Hi Limit switches must not be adjusted or disabled.