Appendix C Troubleshooting and CommonQuestions
PCI Serial for Windows Me/9x C-4 ni.com
Address Test Failed
If the address test failed, Interrupt test cannot be 
performed error message appears, you might have an address conflict 
with legacy boards in your system. To solve this problem, change the base 
addresses assigned to your legacy boards and refer to the Resolving 
Resource Conflicts with Legacy Boards section later in this appendix.
Interrupt Test Failed
If the Interrupt test failed error message appears, you might have 
an IRQ conflict with legacy boards in your system. To solve this problem, 
change the IRQ level assigned to your legacy boards and refer to the next 
section, Resolving Resource Conflicts with Legacy Boards.
Resolving Resource Conflicts with Legacy BoardsResource conflicts typically occur if your system contains legacy boards 
that use resources that are not reserved properly. If a resource conflict 
exists, write down the resource that caused the conflict and refer to the 
Microsoft Windows Me/9x user’s guide for instructions on how to use the 
Device Manager to reserve I/O and IRQ resources for legacy boards.
Forcing Windows to Detect Your HardwareIf Windows Me/9x did not display the New Hardware Found dialog box, 
it did not detect your hardware. To solve this problem, complete the 
following steps:
1. Select Start»Settings»Control Panel and double-click on the 
System icon.
2. Click on the Device Manager tab and click on the View devices by 
type button.
3. Double-click on the Other Devices icon. Windows Me/9x lists the 
boards it does not recognize under Other Devices.
4. Double-click on the Multi-function adapters icon, where 
WindowsMe/9x lists the parent devices of the PCI ports.