© National Instruments Corp. 11 NI 9426 Operating Instructions and Specifications
Hold time1.........................................0 s min
Setup time2........................................1 μs min
Update/transfer time3........................7 μs max
MTBF............................................... 955,723 hours at 25 °C;
Bellcore Issue 2, Method 1,
Case 3, Limited Part Stress
Method
Note Contact NI for Bellcore MTBF specifications
atother temperatures or for MIL-HDB K-217F
specifications.
1 Hold time is the amount of time input signals must be stable after initiating a read
from the module.
2 Setup time is the amount of time input signals must be stable before reading from the
module.
3 The update/transfer time is valid when the module is used in a CompactRIO system.
When used in other systems, driver software and system latencies impact this time.