This category refers to local-level electrical distribution, such as
that provided by a standard wall outlet, for example, 115 V for U.S.
or 230 V for Europe.
Caution Do not connect the NI 9472/9474 with screw
terminal to signals or use for measurements within
Measurement CategoriesIII or IV.
NI 9472 with DSUB Safety VoltagesConnect only voltages that are within the following limits.
Channel-to-COM.............................. 30 VDC max
Isolation
Channel-to-channel.................... None
Channel-to-earth ground
Continuous........................... 60 VDC,
MeasurementCategory I
Withstand.............................1,000 Vrm s, verified by a 5 s
dielectric withstand test
Measurement Category I is for measurements performed on
circuits not directly connected to the electrical distribution system
referred to as MAINS voltage. MAINS is a hazardous live electrical