© National Instruments Corporation 5 NI PXI-1006 Power Supply Shuttle User Guide
DC OutputMaximum usable power.........................600 W
DC current capacity (IMP)
Load regulation
Maximum ripple and noise.................... 1% ripple, 1% noise
20 MHz bandwidth
Over-current protection..........................105–140% of rated output
current; automatic recovery
Over-voltage protection......................... 3.3 V, 5 V clamp at 122–134%
ofoutput voltage
+12 V and –12 V clamp at
110–120% of output voltage
Power supply shuttle MTTR..................Replacement in under 5 minutes
Volt age IMP (Steady-State Current)
+3.3 V 60 A
+5 V 60 A
+12 V 9 A
–12 V 1.8 A
Volt age Regulation
+3.3 V 0.4% or 20 mV max
+12 V 0.4% or 20 mV max
+5 V 0.4% or 20 mV max
–12 V 0.4% or 20 mV max