Appendix A Specifications
© National Instruments Corporation A-3 MXI-Express Series User Manual

Shock and Vibration

Operational shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)

Random Vibration

Operating................................................5 to 500 Hz, 0.3 grms
Nonoperating..........................................5 to 500 Hz, 2.4 grms
(Tested in accordance
with IEC-60068-2-64.
Nonoperating test profile
exceeds the requirements of
MIL-PRF-28800F, Class 3.)
NI PCIe-8360
Maximum altitude..................................2,000 m
Pollution Degree.................................... 2
Indoor use only

Operating Environment

Ambient temperature range....................0 to 40 °C (tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2)
Operating relative humidity................... 10 to 90%, noncondensing
(tested in accordance with
IEC-60068-2-56)

Storage Environment

Ambient temperature range....................–20 to 70 °C (tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2)
Storage relative humidity....................... 5 to 95%, noncondensing
(tested in accordance with
IEC-60068-2-56)