© National Instruments Corporation 17 NI USB-6008/6009 User Guide and Specifications
AI FIFOThe NI USB-6008/6009 can perform both single and multiple A/D
conversions of a fixed or infinite number of samples. A first-in-first-out
(FIFO) buffer holds data during AI acquisitions to ensure that no data
is lost.
Analog Input ModesYou can configure the AI channels on the NI USB-6008/6009 to take
single-ended or differential measurements. Refer to Table6 for mo re
information about I/O connections for single-ended or differential
measurements.
Connecting Differential Voltage SignalsFor differential signals, connect the positive lead of the signal to the
AI+t erminal, and the negative lead to the AI– terminal.
Figure 8. Connecting a Differential Voltage Signal
The differential input mode can measure ±20 V signals in the ±20V range.
However, the maximum voltage on any one pin is ±10 V with respect to
GND. For example, if AI 1 is +10 V and AI 5 is –10 V, then the
measurement returned from the device is +20 V.
AI+
NI USB-6008/6009
AI–
Voltage
Source