© National Instruments Corporation 5 NI 6509 User Guide and Specifications
Panel Mounting
To mount the NIUSB-6509 to a board or panel, complete the following
steps while referring to Figure 3.
Figure 3. Mounting the NI USB-6509 on a Panel
Notes Do not apply the rubber feet to the NI USB-6509 when panel mounting the device.
Apply strain relief, as described in the USB Cable Strain Relief section, before panel
mounting the NI USB-6509.
1. Go to ni.com/info and enter the info code rd3233 to download and
print the panel mounting template PDF.
2. Using the template, mark the bottom point and top point on the panel.
The points will be 162 mm (6.375 in.) from each other.
3. Remove the USB cable from the connector on the NIUSB-6509.
4. Screw a #8 or M4 screw into the bottom point on the panel.
5. Set the NI USB-6509 on the screw by fitting it into the bottom screw
notch on the underside of the NI USB-6509.
6. Screw a #8 or M4 screw through the NIUSB-6509 to p screw hole into
the panel.