© National Instruments Corporation 7 NI USB-9229/9239 User Guide and Specifications

Installing Other Software

If you are using other software, refer to the installation instructions that
accompany your software.

Example Programs

The NI-DAQmx CD contains example programs that you can use to get
started programming with the NI USB-9229/9239. Refer to the NI-DAQmx
for USB Devices Getting Started Guide that shipped with your device, and
is also accessible from Start»All Programs»National Instruments»
NI-DAQ, for more information.
Installing the NI USB-9229/9239 Device
Before installing the device, you must install the software you plan to use
with the device. Refer to the Installing the Software section of this guide
and the documentation included with the software for more information.

Installing the NI 9229/9239 Device into the NI USB-9162 Carrier

The NI 9229/9239 module and NI USB-9162 carrier are packaged
separately. Refer to Figure 4, while completing the following assembly
steps:
1. Make sure that no signals are connected to the NI 9229/9239 module
and the USB cable is not connected to the device.
2. Remove the protective cover from the 15-pin D-SUB connector.
3. Align the I/O module with the carrier, as shown in Figure4.
Figure 4. Module Installation
4. Squeeze the latches and insert the NI 9229/9239 module into the
NIU SB-9162 carrier.