Chapter 2 Configuration and Installation
© National Instruments Corporation 2-15 PC-DIO-96 User Manual
Mode 1 Input Timing
The following figure illustrates the timing specifications for an input transfer in mode 1.
T3 T5
T6
T7
T4
T1
T2
STB*
IBF
INTR
RD*
DATA
Name Description Minimum Maximum
T1 STB* pulse width 100 –
T2 STB* = 0 to IBF = 1 – 150
T3 Data before STB* = 1 20
T4 STB* = 1 to INTR = 1 – 150
T5 Data after STB* = 1 50
T6 RD* = 0 to INTR = 0 – 200
T7 RD* = 1 to IBF = 0 150
All timing values are in nanoseconds.