Chapter 3 Signal Connections
© National Instruments Corporation 3-5 PC-OPDIO-16 User Manual
Signal Connection ExampleFigure 3-2 shows signal connections for the load connected to an isolated output.5.6 kΩ5.6 kΩ5.6 kΩ
PC-OPDIO-16
TLP121
Isolation
5.6 kΩ
+
-
Load
Digital Logic
+5 V
VCCO
VOUT
COM
IOH
Isolated Ground
470 Ω
5.6 kΩ5.6 kΩ5.6 kΩ
Isolation
5.6 kΩ
+
-
Load
Digital Logic
+5 V
VCCO
VOUT
COM
IOL
Isolated Ground
470 Ω
Supply
5–24 VDC
a. Load sinking currentb. Load sourcing currentPC-OPDIO-16
Supply
5–24 VDC
Figure 3-2.  Signal Connection Example for Isolated Output