Status Codes Appendix D
PC-OPDIO-16 User Manual D-2 © National Instruments Corporation
Table D-1. Status Code Summary (Continued)
Status Code Status Name Description
8readOutputLine A digital line configured for output has been read.
7relatedPortBusy Another port on the same chip is busy. Config and setup call
may corrupt its signal lines.
6noPreTrigUnwrap Allocation of array to hold the final indices to use in unwrapping
pretrigger frames failed in MDAQ_Start.
5calibrationErr A2000 gain and offset dac calibration failed during init.
4readOutputPort A digital port configured for output has been read.
3dupDMALevels Two or more boards have the same DMA level.
2dupIntLevels Two or more boards have the same interrupt level.
1dupIOaddrRange The address space of two or more boards overlaps.
0noErr No error occurred; call was successful.
-60 notOurBrdErr The board in the specified slot is not a National Instruments data
acquisition board.
-61 badBrdNumErr The board parameter is out of range.
-62 badGainErr The gain parameter is out of range.
-63 badChanErr The chan parameter is out of range.
-64 noSupportErr Function cannot be executed by the specified board.
-65 badPortErr The port parameter is out of range or the port is busy.
-66 badOutPortErr The specified port has not been configured as an output port.
-67 noLatchModeErr Port does not support latched mode (config call).
-68 noGroupAssign The specified port cannot be assigned to a group.
-69 badInputValErr One or more input parameters are out of range.
-70 timeOutErr A/D conversion did not complete or timeout period has expired.
-71 outOfRangeErr Scaled input value is out of range.
-72 daqInProgErr Data acquisition is in progress; therefore, call was not executed.
-73 counterInUseErr The specified ctr is currently in use; therefore, call was not
executed.
-74 noDAQErr No data acquisition is in progress; call had no effect.
-75 overFlowErr A/D FIFO memory has overflowed as a result of a DAQ or
SCAN operation.
-76 overRunErr Minimum sample interval has been exceeded as a result of a
DAQ or SCAN operation.
-77 badCntErr The count does not conform to an integer multiple of
numChans (SCAN_Start call) or the count is not divisible by
2 when configured for double buffering.
-78 brdTypeErr Board type is incompatible with the function called.
-79 noCountOpErr The specified ctr is not configured for an event-counting
operation.
-80 ctrReservedErr The specified ctr is reserved for data acquisition operations
only.
(continues)