Appendix A Specifications
© National Instruments Corporation A-3 MXI-4 Series User Manual
Random VibrationOperating................................................5 to 500 Hz, 0.3 grms
Nonoperating..........................................5 to 500 Hz, 2.4 grms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
SafetyThe MXI-4 cards were evaluated using the criteria of EN 61010-1 and meet
the requirements of the following standards for safety and electrical
equipment for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 3111-1, UL 61010B-1
• CAN/CSA C22.2 No. 1010.1
Note For UL and other safety certifications, refer to the product label, or visit
ni.com/hardref.nsf, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic CompatibilityEmissions...............................................EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity................................................EN 61326:1997 + A2:2001,
Table 1
EMC/EMI...............................................CE, C-Tick, and FCC Part 15
(Class A) Compliant
Note For EMC compliance, operate this device with shielded cabling. Inaddition,
all covers and filler panels must be installed.