Appendix A Specifications
© National Instruments Corporation A-3 NI PXI-8105 User Manual
Shock and Vibration
Operational shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating........................................ 5 to 500 Hz, 0.3 grms
(with solid-state hard drive)
Nonoperating.................................. 5 to 500 Hz, 2.4 grms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
andlaboratory use:
IEC 61010-1, EN 61010-1
UL 61010-1
CAN/CSA-C22.2 No. 61010-1
Note For UL and other safety certifications, refer to the product label or to
ni.com/certification, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions...............................................EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity................................................EN 61326:1997 + A2:2001,
Table 1
EMC.......................................................CE, C-Tick, and FCC Part 15
(Class A) compliant
Note For full EMC compliance, operate this device with shielded cabling.