Appendix A Specifications
©
National Instruments Corporation A-3 PXI-1000 User Manual
CoolingSafety
Table A-3. Cooling Specifications
Characteristic Description
Per Slot Cooling Capacity Slot cooling capacity in worst-case slot
is2 0 W with fan speed set to HI
Module Cooling System Forced air circulation (positive
pressurization) via two 60 cfm fans with
HI/LO speed selector
Slot Airflow Direction P1 to P2, bottom of module to top of
module
Module Cooling Intake Bottom rear of mainframe
Module Cooling Exhaust Along both sides of mainframe
Power Supply Cooling
System Forced air circulation via integrated fan
Power Supply Cooling
Intake Rear of mainframe
Power Supply Cooling
Exhaust Along both sides of mainframe rear and
upper rear panel
Module Cooling Fan
MTBF 40,000+ hr
Power Supply/Fan Unit Replacement in under 5 minutes
Table A-4. Safety Specifications
Characteristic Description
Safety Characteristics UL 3111-1, IEC 1010-1, CSA 22.2
No.1010.1
Installation Category II
Pollution Degree 2
Safety Class 1