49
3. Loosen the two screws sec uring the lamp housing until the phillips screwdriver goes into a freewhee l-
ing condition.
The two screws are not removable.
Remove the lamp housing by holding the handle.
6. Maintenance
NOTE: There is an interlock on this case to prevent the risk of electrical shock. Do not atte mpt to circumvent this interlock.
4. Push the part as shown on t he drawing and insert a new lamp housing until it is plugge d into the socket.
CAUTION
Do not use a lamp other than the NEC replacement lamp NP03LP (NP60) or NP0 2LP (NP50/NP40).
Order this from your NEC dealer.
Secure it in place with the two screws.
NOTE: Tighten the two screws alternately until both screws are completely tightened. Failure to do thi s can result in air leak
from the cooling pump, causing the pump error. (→ page 52)
1
2
Interlock
5. Reattach the lamp cover.
Tighten the lamp cover screw.
Be sure to tighten the screw.