CHAPTER 5 CLOCK GENERATOR
98 User’s Manual U15331EJ4V1UD
5.3 Registers Controlling Clock Generator
The clock generator is controlled by the following four registers.
• Processor clock control register (PCC)
• Subclock oscillation mode register (SCKM)
• Subclock control register (CSS)
• Subclock selection register (SSCK) (
µ
PD78F9488, 78F9489 only)
(1) Processor clock control register (PCC)
This register is used to select the CPU clock and set the frequency division ratio.
PCC is set with a 1-bit or 8-bit memory manipulation instruction.
RESET input sets this register to 02H.
Figure 5-3. Format of Processor Clock Control Register
Symbol <7> 6 5 4 3 2 <1> 0 Address After reset R/W
PCC MCC 0 0 0 0 0 PCC1 0 FFFBH 02H R/W
MCC Main system clock oscillator operation control
0 Operation enabled
1 Operation stopped
Minimum instruction execution time: 2/fCPU
CSS0 PCC1 CPU clock (fCPU) selectionNote
fX = 5.0 MHz or fXT = 32.768 kHz
0 0 fX 0.4
µ
s
0 1
fX/22 1.6
µ
s
1
× fXT/2
4fXT (when ×4 multiplication circuit is used)
122
µ
s
15.26
µ
s (when ×4 multiplication circuit is used)
Note The CPU clock is selected by a combination of flag settings in the PCC and CSS registers. (Refer to
5.3 (3) Subclock control register (CSS).)
Cautions 1. Always set bits 0 and 2 to 6 to 0.
2. MCC can be set only when the subsystem clock is selected as the CPU clock.
Setting MCC to 1 while the main system clock is operating is invalid.
Remarks 1. fX: Main system clock oscillation frequency
2. fXT: Subsystem clock oscillation frequency