2. To complete this installation, follow the basic masonry fireplace trim kit
instructions EXCEPT:
The trim kit may have to be cut down in size so as not to block any cooling
vents/chambers of the Zero Clearance Fireplace.
3. To complete methods 1 and 2, position the heater into the ZC Fireplace and center
the flue exit under the connection.
4. Slide the connector (or slip connector) down into the flue exit of the heater approx-
imately 3/8". Now, seal the connector to the heater (and fireplace throat if method #1 is
used) using refractory cement.
CAUTION: Do not loosen the ceramic brick.
CAUTION: Crimped end of connector must be placed into the heater throat.
5. Check installation minimum clearances and install an approved heater extension
or floor protector to meet at least the minimum clearances.
14