CL - clear data function: upon pressing the Action button (6) (fig. 1) the entire data on all previous measurements will be erased.
4. TECHNICAL CHARACTERISTICS
NOTE: After changing a battery the recall stack should be cleared by exercising the CL mode.
OVER 100 – allows to ignore targets closer than 100m. Useful when looking through bush.
Please note: this is an optional feature on early designs. Latest version includes automatic “Last Target” selection that renders obsolete the requirement for a separate manual mode selection.
c. Reflection
Distance measuring procedure includes instant statistical processing of the package of single measuring sessions. Qualitative result of the statistical processing is presented on the Display as a message TARGET REFLECTION (5).
There are four statistical qualifications of the reflected signal:
•NO TARGET REFLECTION – when a reflected signal isn’t received. Numerical display shows 4 dashes in the distance displaying area;
•TARGET REFLECTION LOW – when the number of steady received reflected signals is just enough to make acceptable conclusion about the distance;
1 . O p t i c s Observation Magnification, x Objective Lens, mm Exit Pupil Diameter, mm Eye Relief, mm
Field of View Axial Resolution, ” Image tilt, maximum
-Horizontal
-Vertical
Type of coating Interpupillary Distance, mm Diopter Adjustment range Reticule
Binocular
7
50
7.1
25
5°
6
60”
30”
Fully
±4
Corresponds to laser
direction and approx. size
of the laser on target