IMAGE INTENSIFIER TUBE SPECIFICATIONS
The unit is utilizing a small size image intensifier with direct image transfer.
The tube contains a microchannel plate,
Main parameters:
Spatial frequency-contrast characteristic
Frequency, lines/mm | Contrast transfer | Contrast transfer |
| Coefficient (Gen. 2+) | Coefficient (Gen. 3) |
2.5 | 0.83 | 0.86 |
7.5 | 0.56 | 0.58 |
15.0 | 0.26 | 0.28 |
Field of view cleanness
Image Intensifier Type (Generation) | 2+ | 3 |
Photocathode operating diameter, mm | 18 |
|
Photocathode type | A3B5 (GaAs) | |
Resolution, lines/mm | ||
Photocathode sensitivity, min: |
|
|
Integral, ∝A/ lm | ||
Spectral at λ = 850 nm, mA/W | 15 | 90 |
Light amplification | ||
Image magnification | 1 |
|
Dark background brightness, max, cd/m2 | 1⋅10 −3 | 3⋅10 −3 |
Zone
#
Gen. 2+
1
2
3
Gen. 3
1
2
3
Zone
Diameter,
Mm
0 – 9.0
9.0- 14.4 14.4
0 – 8.75
8.75– 14.0
14.0– 18
Maximum diameter of defects | Admitted total | ||
Neglected | Admitted | area of defects, | |
| ∅, mm | mm2 | |
0.10 | 0.15 | 2 | 0.15 |
0.12 | 0.25 | 3 | 0.30 |
0.15 | 0.35 | 3 | 0.50 |
|
|
|
|
0.06 | 0.15 | 1 | 0.072 |
0.08 | 0.25 | 2 | 0.27 |
0.10 | 0.35 | 3 | 0.45 |
Current consumption, max, mA | 20 | 25 |
Voltage, V | 2.8 ± 0.8 |
|
Weight, g | 55 |
|
4. CONSTRUCTION
23
5
Dimensions |
|
Length, mm | 22.5 |
Diameter, mm | 43.0 |
1.
4
Tube life until reduced parameters, hrs | 10,000 | 10,000 |
Keep time, years | 12 | 15 |
Ambient temperature range, °C | ± 40 | ± 50 |
2.Mounting Socket
3.
4.Eyepieces
5.Battery House Cover
6. Objective Lens focus | 6 | 1 |
| ||
|
| |
|
| Figure 1 |