LEAK TESTING
GAS FLOW CHECK
Each grill burner is tested and adjusted at the
factory prior to shipment; however, variations
in the local gas supply may make it necessary
to adjust the burners. The flames of the
burners should be visually checked.
Flames should be blue and stable with no
yellow tips, excessive noise or lifting. If any
of these conditions exist, check to see if the air
shutter or burner ports are blocked by dirt,
debris, spider webs, etc. If you have any
questions regarding flame stability, please call
customer service 1-800-913-8999.
Check all gas supply fittings for leaks before
each use. It is handy to keep a spray bottle of
soapy water near the shut-off valve of the
gas supply line. Spray all the fittings.
Bubbles indicate leaks.
ALWAYS CHECK FOR LEAKS AFTER
EVERY L.P. TANK CHANGE
Disconnected L.P. cylinders must have
threaded valve plugs tightly installed, and
must not be stored in a building, garage or
any other enclosed area.
The gas must be turned off at the supply
cylinder when the unit is not in use.
If the appliance is stored indoors the
cylinder must be disconnected and removed
from the appliance. Cylinders must be
stored outdoors in a well-ventilated area out
of the reach of children.
INSTALLER FINAL CHECK LIST9Specified clearance maintained 24”
from combustibles.
9All internal packaging removed.
9Knobs turn freely.
9Burners are tight and sitting properly
on orifices.
9Pressure regulator connected and set
for 11.2” W.C. L.P. gas. Gas
connections to grill using hose &
regulator assembly provided (pre-set for
11.0” water column).
9Unit tested and free of leaks.
9User informed of gas supply shut off
valve location
USER, PLEASE RETAIN THESE
INSTRUCTIONS FOR FUTURE
REFERENCE.
PROPANE CYLINDER CAUTIONS
a) Do Not store a spare LP-gas cylinder
under or near this appliance.
b) NEVER fill the cylinder beyond 80
percent full.
c) If the information in “a” and “b” is not
followed exactly, a fire causing death or
serious injury may occur.
15
CHECK LIST