9. APPLY POWER - SELECT DIALING METHOD

TURN POWER

SWITCH ON

ON

NOTE: THE DEFAULT DIALING METHOD IS TONE DIALING

IF REQUIRED, CHANGE THE DIALING METHOD BY PRESSING AND HOLDING THE HOME & CLEAR BUTTONS WHILE SWITCHING THE POWER ON

7 BEEPS SOUND FOR PULSE DIALING

8 BEEPS SOUND FOR TONE DIALING

11.INSTALLING SINGLE TRANSMITTERS

ADDS ONE TRANSMITTER AT A TIME

1 PRESS CLEAR BUTTON FOR 5 SECONDS

• 5 BEEPS SOUND

(TX ADD MODE)

2ACTIVATE TRANSMITTER

• 1 BEEP SOUNDS

(TX ADDED) CONSOLE REVERTS TO OPERATE MODE

NOTE: IF THE CONSOLE'S MEMORY

 

IS FULL, ONE LONG BEEP SOUNDS WHEN

DXS-62A

TRYING TO ADD A TRANSMITTER

3REPEAT STEPS 1 & 2 FOR ADDITIONAL TRANSMITTERS (UP TO 16 TOTAL)

NOTE: PRESS CLEAR BEFORE TRANSMITTING TO RETURN TO OPERATE MODE WITHOUT ENTERING A TRANSMITTER

2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED

3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED

THE CONSOLE WILL RETURN TO OPERATE MODE AUTOMATICALLY AFTER 30 SECONDS

NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER.

10. TRANSMITTER INSTALLATION OPTIONS

FOR ALL TWO-BUTTON TRANSMITTERS

WHEN IT IS

IT WILL

ACTIVATE

INSTALLED

USING

WITH THE

EITHER

LEFT BUTTON

BUTTON

 

WHEN IT IS

IT WILL ONLY

INSTALLED

ACTIVATE

WITH THE

USING BOTH

RIGHT BUTTON

BUTTONS

FOR DXS-31 STATIONARY TRANSMITTERS

WHEN IT IS INSTALLED

WHEN IT IS INSTALLED

WITH THE JUMPER SET

WITH THE JUMPER SET

FOR DELAY

FOR INSTANT

IT WILL

IT WILL

FUNCTION

FUNCTION

AS EMERGENCY

AS ACTIVITY

FOR MODEL DXS-32: CUT JUMPER (INSTANT TX) FOR USE

AS AN ACTIVITY TX. SEE DXS-32 INSTALLATION INSTRUCTIONS

12. INSTALLING MULTIPLE TRANSMITTERS

ADDS MULTIPLE TRANSMITTERS

1 PRESS TEST BUTTON

• 4 BEEPS SOUND (TEST MODE)

2 PRESS TEST BUTTON AGAIN

• 5 BEEPS SOUND

(ADD TX MODE)

NOTE: EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TX MODE, THE CONSOLE WILL BE READY TO INSTALL A TRANSMITTER IN THE NEXT AVAILABLE SENSOR ZONE LOCATION. IF THE VB-4B VOICE BOARD IS INSTALLED, THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION NUMBER.

3 ACTIVATE TRANSMITTER

• 1 BEEP SOUNDS (TX ADDED)

NOTE: IF THE CONSOLE'S MEMORY

IS FULL, ONE LONG BEEP SOUNDS

WHEN TRYING TO ADD A TRANSMITTER

4 REPEAT STEPS 2 & 3 FOR

DXS-62A

 

ADDITIONAL TRANSMITTERS

 

(UP TO 16 TOTAL)

 

5PRESS CLEAR TO RETURN TO OPERATE MODE

2 BEEPS SOUND WITH ACTIVITY TIMER ENABLED

3 BEEPS SOUND WITH ACTIVITY TIMER DISABLED

THE CONSOLE WILL RETURN TO OPERATE

MODE AUTOMATICALLY AFTER 3 MINUTES

NOTE: WRITE DOWN EACH TRANSMITTER'S TYPE AND ZONE NUMBER WHEN THE TRANSMITTER IS ADDED. THE CENTRAL STATION WILL NEED TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER

3

Page 5
Image 5