MAINTENANCE SCHEDULE
MAINTENANCE ITEM | WEEKLY | MONTHLY | YEARLY |
Clean the Brush | X |
|
|
Clean the | X |
|
|
Check the Power Cord | X |
|
|
Clean the Spray Nozzle |
| X |
|
Lubricate the Machine |
| X |
|
Check the Vacuum Motor Airways |
| X |
|
*Check the Vacuum Motor Brushes |
|
| X |
*Have Nilfisk check the carbon motor brushes once a year or after 500 operating hours.
STORING THE MACHINE
Store the machine indoors in a clean, dry place. Keep from freezing. Leave the tanks open to air them out..
WARNING!
To reduce the risk electric shock or injury, unplug the power cord before servicing.
BRUSH MAINTENANCE
Once a week (or more often if necessary), remove debris from the brush.
PICK-UP TOOL MAINTENANCE
Once a week (or more often if necessary), remove debris from the
POWER CORD MAINTENANCE
Once a week (or more often if necessary), check the power cord for cracked or damaged insulation, exposed wires in the cord or plug, and damaged or missing ground pin. Repair or replace damaged cord or plug immediately.
SPRAY NOZZLE MAINTENANCE
Once a month (or more often if necessary), remove the spray nozzle from the machine and soak it overnight in a vinegar and water rinse to remove chemical deposits.
The spray nozzle is located just behind the brush, on the bottom of the machine.
Die Spritzdüse ist knapp hinter der Bürste, unten an der Maschine, angeordnet.
12 - FORM NO. 56041590 / AX 300 / AX 400