Assembly, Servicing & User InstructionsWarning: Only for outdoor use

The Hotspot Patio Heater Range

Terrace

Spiral Bullet

TECHNICAL DATA
Heat input 14kw (50) 11kw (37)
Gas consumption 0.9 kg/h
Category: Main injector Injector Pilot injector Inlet pressure
size identification size
I3B/P 1.95mm 0.25mm 30mbar
I3B/P 1.65mm 0.25mm 50mbar
I3+ 1.95mm 0.25mm 28/37mbar
APPLIANCE IDENTIFICATION
Material group: 11.02 Radiant heater
Manufacturer: Hotspot
Trade name: Hotspot
Type: Bullet, Evolution and Terrace
Category and DK, FI, NL, NO, SE I3B/P – 30 mbar
country of AT, DE I3B/P – 50 mbar
destination BE, ES, FR, GB, GR, IE, IT, LU, PT I3+ – 28 / 37 mbar
Appliance Pin Number: 048BM - 0022 (conical) 048BM - 0018 (straight)
For UK use 37 mbar regulator with Propane Gas