Nilfisk-ALTO SPS-28 E manual Capacitor Test, Diode Test

Models: SPS-28 E

1 28
Download 28 pages 2.39 Kb
Page 15
Image 15
Capacitor Test

Capacitor Test

If a commercial capacitor checker is not available, the following test may be made:

1.Briefly short the capacitor terminals together with a screwdriver.

2.Disconnect a wire from either capacitor terminal.

3.Adjust an ohmmeter to a high value such as RX10K or RX1 Meg.

4.Connect the ohmmeter leads to the capacitor terminals.

5.A good capacitor will cause the indicator to move quickly to zero ohms, then slowly return to infinite ohms. An open capacitor will not cause any indicator movement; a shorted capacitor will give a continuous zero ohms reading.

6.If the test is to be repeated, the capacitor terminals must again be shorted together briefly.

Diode Test

1.You must have a #308 ct. Everready continuity tester or equivalent/

2.Desolder both wires from the diode lead connections. (Clamp heatsink pliers on the diode leads to avoid damaging the diodes.)

3.Attach one of the test unit leads to either diode lead.

4.Attach the other test unit lead to the diode heatsink.

5.Turn the test unit on and note if the test unit bulb lights.

DANGER: Reversing charge or polarity of wiring couldcausebatteriestoEXPLODEcaus- ing serious bodily harm to yourself or others.

6.. Reverse the test unit leads in Steps 3 and 4.

7.Turn the test unit on and note if the test unit bulb lights.

8.Good diode - test light bulb should light up in one of Steps 5 and 7 and not in the other.

Defective diode - test bulb will light up in both Steps 5 and 7.

Defective Diode - Test bulb will not light up in either Steps 5 or 7.

CLARKE TECHNOLOGY Model SPS-28 Space Sweeper Operator's Manual

Page 15

Page 15
Image 15
Nilfisk-ALTO SPS-28 E manual Capacitor Test, Diode Test

FAQ

How do I test the capacitor of my Nilfisk-ALTO SPS-28 E vacuum cleaner?

You can test the capacitor using a commercial capacitor checker or by following the step-by-step instructions provided in the manual.

How do I perform a diode test on my Nilfisk-ALTO SPS-28 E vacuum cleaner?

You can perform a diode test using a #308 ct.Everready continuity tester or an equivalent device as outlined in the official operator's manual.

What should I do if the diode test unit bulb lights up in both Steps 5 and 7?

If the diode test unit bulb lights up in both Steps 5 and 7, it indicates a defective diode-test bulb that needs to be replaced.