 8
Figure4–Frontviewwithoutfrontbezel
OncetheExtranetSwitchhasbeenconfiguredinitsFIPS140-1level2mode,thecover
maynotberemovedwithoutsignsoftampering.Tosealthecover,applythreeserialized
tamper-evidentlabelsasfollows:
1. Cleanthecoverofanygrease,dirt,oroilbeforeapplyingthetamper-evidentlabels.
Alcoholbasedcleaningpadsarerecommendedforthispurpose.Thetemperatureof
theswitchshouldbeabove10°C.
2. Applytwo(2)labelsonthetopcoveroverlappingthesideandtherearofthechassis
asshowninFigure5.
3. Applytwo(2)labelsonthetopandbottomoverlappingthefrontbezelasshownin
Figure5.
4. Applyone(1)labeloverthekeyboardbuttoncoverasshowninFigure5.
5. Recordtheserialnumbersofthelabelsappliedtothemodule.
6. Allow24hoursfortheadhesiveinthetamper-evidentsealstocompletelycure.