North Star M1573001A owner manual Skin puncture hazard

Models: M1573001A

1 24
Download 24 pages 28.83 Kb
Page 12
Image 12

Operation Instructions

START-UP INSTRUCTIONS

SHUT-DOWN INSTRUCTIONS

1.

Attach garden hose.

1.

Turn motor OFF.

2.

Attach pressure hose.

2.

Unplug the power cord.

3.

Attach gun and lance.

3.

Turn water supply OFF.

4.

Turn water supply ON.

4.

Squeeze trigger to

5.

Squeeze trigger to

 

relieve system pressure.

 

purge air from pump.

5.

Remove garden hose.

6.

Insert nozzle.

6.

Remove pressure hose.

7.Plug in power cord

8.Reset the GFCI button on the cord

9.Start motor.

WARNING

Skin puncture hazard.

High pressure fluid can inject under skin resulting in serious injury including amputation. Do not direct spray at people or animals.

-If skin injection happens, seek IMMEDIATE surgical treatment.

-Do not check for leaks with hand. Instead, use a piece of cardboard to check for leaks.

-Do not use unit if exterior hose damage is evident. Make sure all fittings are tight before starting. Relieve system pressure before servicing.

-Know how to stop engine and bleed pressures quickly. Be thoroughly familiar with the controls.

-Make sure accessories meet the unit's temperature and pressure limits. -Stop engine and bleed pressures before leaving unit unattended.