Troubleshooting
Problem |
|
Engine will not start | SOLUTION: A |
Low/Surging pressure or no water flow | SOLUTION: B,C,D,E,F,G |
No chemical injection | SOLUTION: H,I,J,K |
Cause | Solution |
A- Engine starting instructions not followed | See engine manual for starting instructions |
B- Insufficient water supply | See water supply section of this manual |
C- Plugged pump inlet filter | See maintenance section of this manual |
D- Wrong nozzle | Make sure high pressure nozzle is being used |
E- Plugged nozzle | Remove nozzle, check for blockage |
F- Worn nozzle | Replace nozzle |
G- Leak in pressure hose | Replace pressure hose |
H- Wrong nozzle | Make sure chemical nozzle is being used |
I- Back pressure from extra long pressure hose | Use standard length hose |
J- Leak in chemical siphon hose | Replace hose – use hose clamps if necessary |
K- Chemical strainer not submerged | Make sure strainer is completely submerged |
Specifications
1577541
PSI (bar) | 2600 (179) |
GPM (l/min) | 2.5 (9.4) |
Max Water Temp | 140°F (60°C) |
Noise Level | 75 dB |
Dimensions | 30.5 x 24 x 24.3 |
L x W x H |
|
Weight | 77 lbs |
1577542
PSI (bar) | 2700 (186) |
GPM (l/min) | 2.5 (9.4) |
Max Water Temp | 140°F (60°C) |
Noise Level | 82 dB |
Dimensions | 30.5 x 24 x 24.3 |
L x W x H |
|
Weight | 83 lbs |
The manufacturer reserves the right to make improvements in design and/or changes in specifications at any time without incurring any obligation to install them on units previously sold.
Any Questions, Comments, Problems or Parts Orders
Call Northstar Customer Service
21