OIL EXTRACTION

Fig.2Connect compressed air 100PSI (7bar) to quick couple D. Open the ball

Valve C. Air will flow out from the muffler E. When the arrow of the vacuum gauge approaches the red field, after 70-80 seconds, close the ball valve C, then shut off the compressed air. The aspiration oil is now ready for use.

OIL EXTRACTION

Oils should always be removed when they are hot (158º-176ºF). The suction capacity of the unit is equal to 2/3 of its reservoir capacity.

Insert the probe into the dipstick tube. Connect the probe to the unit. Open ball valve A taking care to keep the probe near the bottom of the sump.

EMPTYING THE ASPIRATION OIL

Remove the cap B and manually drain the oil.

First open suction valve A.

CAUTION!

Do not completely overturn the reservoir.

The drained fluids should not come into contact with the oil changer’s venturi valve. If this happens, unscrew the muffler and blow it out with compressed air.