Specifications |
|
Form C Relay Contacts |
|
Max. switching power | 60W, 125VA |
Max. switching voltage | 220 VDC, 250 VAC |
Max. switching current | 2A DC or AC |
Max. carrying current | 2A DC or AC |
Sonalert Audible Horn |
|
Loudness | 80dbA min. |
Variable volume control in rear |
|
12 Volt Alarm Power Supply (Required for Alarm Functions Only)
Input Voltage Range | 100 - 240 VAC, |
| 0.4A |
Output Voltage | 12V at 1.25A max. |
USB 1.0/2.0 Compatible | |
Data Exchange Rate | 12 Mbps |
Current draw | 100 ma. max. |
Supplied interface cable | 3 meters |
PC Connector | USB A Male |
Keyboard Connector | USB B Male |
CE Certification
Copy of certificate is available upon request.
Installation CD
Includes installation procedure and USB Driv- ers and Virtual COM Port Software for Windows 2000, XP, Vista, and Server 2003.
Compatibility
The D/3 USB Keyboard is compatible with all Windows OCMs supporting USB 1.0/2.0 connec- tions.
Copyright © 2007 NovaTech, LLC. All rights reserved. All trademarks are prop- erties of their respective owners. D/3, SABL, and FlexBatch are registered trademarks of NovaTech Process Solutions, LLC. NovaTech is a registered trade- mark of NovaTech, LLC. The information in this literature is subject to change without notice and is not to be construed as a warranty.
DS_USBKB_0607_A4
D/3® USB Keyboard
Process Control Functions
Keys
Alphabetic Keys
*, Q, W,E ,R, T, Y, U, I, O, P, &, DEL, @, A S, D, F, G, H, J, K, L, /, #, SPACE, Z, X, C, V, B, N, M, %, $, :,“, [, ]
Numeric Keys
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, ., -
Display Keys
OVERVIEW, FACEPLATE, SINGLE LOOP, SYSTEM STATUS, GRAPHICS, GROUP LIST, LOOP MAINT, CURR TREND, HIST TREND
Display Function Keys
CLEAR, SAVE, DISPLAY EDIT, COPY, GENERAL FUNCTION, PAGE, PREVIOUS, GRAPHIC ASSOCIA- TION (4), ASSOCIATED DISPLAY, WINDOW SELECT
Quick Select Keys
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
Alarm Keys
ALARM P1, ALARM P2, ALARM P3, SILENCE, ALARM ACK, LAST ALARM
Sequence Logic Keys
UNIT STATUS, UNIT VARS, RECIPE STATUS, PRO- GRAM STATUS, PROGRAM STEPS, MESSAGE ACK, LOAD RECIPE, QUERY HOLD
Digital Function Keys
CLOSE OFF (CMD 0), OPEN ON (CMD 1), CMD #,
OVERRIDE, MID IDLE (CMD 2), CLEAR FAULT
Continuous Control Function Keys
AUTO/MAN, SETPOINT, CASC, OUTPUT, VALUE, Ramp Keys: , , ,
Parameter Modification Keys
CANCEL, MODIFY, SELECT, ENTER
Contact:
NovaTech Europe BVBA | T: | +32 3 458.08.07 |
Kontichsesteenweg 71 | F: | +32 3 458.18.17 |
2630 Aartselaar Belgium | www.novatechweb.com |
®