WIRE THE UNIT

WARNING: Disconnect power at service entrance before wiring this product.

Refer to FIGURE 5

1.Run electrical power cable to installation location. Provide two feet of slack to allow heater to be pulled out far enough to re- move top cover for cleaning or servicing.

NOTE: It is recommended that flexible conduit be used for field wiring to the unit to protect the wires from sharp objects or hazardous environments.

NOTE: Be sure supply voltage meets the equipment requirement. Refer to the rating plate, unit wiring diagram and specification table.

Refer to FIGURE 6

2.Remove top cover for access to wiring box at rear of heater.

Refer to FIGURE 7

3.Remove one of the two knockouts and connect power cable to heater using appropriate connector. Allow at least six inches of wiring inside of wiring box.

4.Connect black to black, white to white and green (or bare wire) to ground screw, as shown. Tuck wires down inside the wiring box.

5.Replace top cover.

WARNING: Do not operate heater without top cover in place.

6. Slide heater into place and secure to mounting surface.

CHECK OPERATION

1.Turn thermostat counterclockwise to its lowest setting.

2.Turn on power to circuit at service entrance.

3.Turn thermostat clockwise. The heating element and fan should come on. Set thermostat to desired temperature level. During proper operation, the heater will cycle on and off periodically.

If heater does not come on:

1.Return the thermostat to lowest setting.

2.Shut off power at service entrance.

3.Remove the top cover, Check for proper line voltage and rein- spect wiring connections. Reread installation procedure mak- ing sure all steps were followed.

4.Also check the thermal fuse. It may be open and need to be replaced. Consult the service parts list for the part number of a replacement fuse. Follow the procedure described in the last paragraph of the warranty when ordering replacement parts.

MAINTENANCE

NOTE: Always disconnect power at service entrance before cleaning or servicing heater.

The only maintenance required for this heater is to periodically vacuum the front grille and housing. Simply remove the two side angle support screws, slide heater out, and remove top cover for access to the blower housing.

FIGURE 5

FIGURE 6

FIGURE 7