MOUNTING THE HOUSING
1.Locate housing between joists.
2.Refer to Figure 5. Using nails, secure hanger bars to joist.
NOTE: The hanger bar brackets are adjustable.
Allowing for the thickness of the finished ceiling, mount hanger bars so that edge of housing will be flush with the finished ceiling.
3. Adjust brackets as required. Tighten brackets.
INSTALLING THE SWITCH
1.Install
2.Refer to Figure 6. Run wiring and make wiring connections.
3.Use supplied screws to secure switch bracket assembly to switch box.
4.Using supplied screws, secure wall plate to switch bracket.
INSTALLING AND CONNECTING THE WIRING
Refer to Figure 6.
All wiring must comply with local codes and unit must be properly grounded.
1.Using
The unit must be wired on a separate 20 Amp circuit.
2.Run wiring from switch location to housing as shown in the wiring diagram.
3.Make wiring connections as shown in wiring diagram.
4.Replace junction box cover. Slide slotted hole in cover over screw. Tighten screw securely.
5.Secure wire cover with one screw.
6.Insert heater and ventilator plugs into proper receptacles as shown.
FIGURE 5 |
MOUNTING THE GRILLE ASSEMBLY
1.Refer to Figure 7. Place the reflector into the grille.
2.Refer to Figure 8. Insert light plug and night light plug into receptacles.
3.Refer to Figure 7. Using two provided screws, secure grille and reflector to housing.
4.Install 100 watt (maximum) light bulb into light socket.
5.Install 7 watt (maximum)
6.Refer to Figure 9. Snap lens into place.
HEATER |
|
|
|
JUNCTION BOX |
|
|
|
HEATER |
|
| LIGHT |
(WHITE) |
|
| |
RED | WHT | WHT | BLK |
|
|
| NIGHT |
|
|
| LIGHT |
|
| WHT | BLK |
NIGHT
LIGHT
HEAT
LIGHT
T
SWITCH
BOX
GROUND | WHITE | BLACK | NOTE: |
|
|
| |
|
|
| WHEN THERMOSTAT |
|
|
| OR TIMER IS USED, |
|
|
| CONNECT AT T |
120vAC | FIGURE 6 |
LINE | |
GRILLE |
|
(LENS OMITTED |
|
FROM DRAWING |
|
FOR ILLUSTRATIVE |
|
PURPOSES) | FIGURE 7 |
|