BLOWER ORIENTATION
IMPORTANT: Be sure the blower is correctly orientated. Note arrow on the side of the blower housing indicating the correct air flow direction (FIGURE 5).
FIGURE 5 – VERTICAL DISCHARGE
VERTICAL
DISCHARGE
VENT
(TOP OF HOOD)
BLOWER
DISCHARGE –
LOCATE AT
DISCHARGE
VENT IN TOP
OF HOOD
THIS
SURFACE
TO REAR
CLEANING INFORMATION
FILTER
For greatest efficiency, the aluminum filters should be removed and cleaned periodically.
To clean, the filter should be soaked in hot water and detergent then thoroughly rinsed. The aluminum filter can be cleaned in a dishwasher.
EXTERIOR SURFACE
To preserve its lasting beauty, clean with a mild detergent. DO NOT use abrasive cleaners.
MOTOR SPEED
TROUBLESHOOTING
If you have a motor speed problem, please check the following list for possible troubles.
1.Knockouts not removed from hood.
2.Blower assembly installed wrong – intended for vertical dis- charge but installed for horizontal discharge and vice versa (FIGURE 5).
3.Damper blade not opening.
4.Duct undersized – reduced airflow because duct too small or too long.
5.Restriction in duct from foreign materials or debris.
6.Undersized or restrictive wall or roof cap.
7.Damper blade in wall or roof cap not opening.
8.Wait for 20 - 30 seconds between speed changes for RPM to adjust.
By removing or correcting these adverse factors, the motor speed control will be able to decrease from maximum RPM.
REPLACEMENT PARTS LIST
Part No. | Description |
R561107 | |
R567073 | Motor, Speed Control |
R730079 | Blower Assembly |
R610038 | Filter |
R566066 | Lampholder |
R520098 | Motor |
R531041 | Blower Wheel CW |
R531042 | Blower Wheel CCW |
MOTOR | LIGHT SWITCH |
CONTROL |
|
JUNCTION
BOX
BLOWER
ASSEMBLY
THUMB
SCREW
BLOWER
COVER
FILTER