Architectural & Engineering Specifications March 2007
DESCRIPTION
BLOWER:
•
•Dynamically balanced centrifugal blower wheel for quiet, efficient performance
•Maintains a high percentage of rated CFM in less than ideal installations
•Low RPM for quiet operation
•Resilient
HOUSING:
•Rugged, 26 gauge, galvanized steel construction
•6” round ducting for superior performance
•Polymeric duct connector with tapered sleeve and no metallic clatter
•
•Sturdy, easy,
•Includes unique spacer (patent pending) for mounting to engineered “I” joists
•Includes hanger bars to position housing anywhere between 16” to
•Two sets of mounting holes for hanger bars allow flush installation with bottom or top of drywall
•Can be mounted in ceilings up to 12/12 pitch
GRILLE:
•Polymeric construction
•Innovative design - the result of extensive research with designers and consumers
•42W fluorescent lamp * (bulb included) and 4W night light (bulb not included)
•Durable steel reflector with white enamel finish
CONTROLS (Purchase separately):
•Refer to NuTone’s catalog for a complete line of accessories to effectively adapt these fans to your construction requirements.
U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit (ceiling mount only).
U.L. Listed for use in insulated ceilings (TYPE I.C.) California Title 24 compliant.
* Use only one of the following 42W fluorescent lamps:
G.E. | F42TBX/835/A/ECO or F42TBX/830/A/ECO or F42TBX/827/A/ECO |
PHILIPS | |
|
|
SYLVANIA | CF42DT/E/IN/835 or CF42DT/E/IN/830 or CF42DT/E/IN/827 |
|
|
NEMA Type | CFTR42W/GX24q/835 or CFTR42W/GX24q/830 or CFTR42W/GX24q/827 |
|
|
Broan | 99271358 |
|
|
QTXEN Series Fan/Light/Night Lights
MODELS QTXEN080FLT, |
QTXEN110FLT, QTXEN150FLT |
ARCHITECT’S SPECIFICATION
•Ceiling Ventilator shall be NuTone Model QTXEN080FLT (QTXEN110FLT) (QTXEN150FLT).
•Ceiling Ventilator shall have corrosion resistant galvanized steel housing with
•Blower assembly shall be removable, have a
•
•Lamp shall be 42W fluorescent * with separate 4W night light.
•Air delivery shall be no less than 80 (110) (150) CFM and sound level no greater than 0.3 (0.7) (1.4) Sones. All air and sound ratings shall be certified by HVI.
•Ceiling ventilator shall be Energy Star® qualified and have an energy efficient permanent split capacitor motor.
•Ceiling Ventilator shall be U.L. Listed for use in insulated ceilings (Type I.C.) and for use over bathtubs and showers when connected to a GFCI protected branch circuit.
INSTALLATION
Complete installation instructions are included with each Fan / Light / Night Light.
NuTone, Inc., 4820 Red Bank Road, Cincinnai, OH 45227
REFERENCE | QTY. | REMARKS | Project |
|
|
|
| Location |
|
|
|
| Architect |
|
|
|
| Engineer |
|
|
|
| Contractor |
|
|
|
| Submitted by | Date |
|
|
| 70C | 99043815D |