READ AND SAVE THESE INSTALLATION INSTRUCTIONS!
Do not supply house power until installation is complete.
All wiring must comply with local electrical codes and the switch must be properly grounded.
Timer w/Single Rocker Switch
TO NUTONE UNIT
WHITE (NEUTRAL) | BLACK (HOT) | BLACK (HOT) | GROUND | GREEN GROUND SCREW |
WHITE (NEUTRAL) | BLACK (HOT) | EARTH GROUND (GREEN) | QUICKWIRE CONNECTIONS |
FIGURE 1
Timer w/Double Rocker Switch
TO NUTONE UNIT
WHITE (NEUTRAL) | BLACK (HOT) | BLACK (HOT) | BLACK (HOT) | GROUND |
WHITE (NEUTRAL) | BLACK (HOT) | EARTH GROUND (GREEN) | QUICKWIRE CONNECTIONS |
FIGURE 2
Timer Switches
MODELS: VS-66WH, VS-67WH,
1.The timer assembly is designed to mount in a
2.Run house power wiring (with ground) from fuse or circuit breaker box and wiring from ventilation fan (refer to Fan motor plate for wiring instructions to motor) to timer and switch in outlet box and make connections as illustrated in Figure 1.
3.Strip wires approximately 1/2" to make connections. Connect wire to terminal screws in the timer side. NOTE: Use
LINE-2/LOAD-2 will turn the current on at the end of timing period.
4.Insert wired switch in wall box with screws provided.
5.Insert wired timer into wall box with “TOP” (indicated on front cover) in proper position. Refer to Figure 2.
6.Fasten timer to wall box using (2) screws provided.
7.Fasten wall plate to timer using (4) screws provided with the plate. The screws must be
8.Position small plastic timer dial so that “OFF” is in the up position. Install hex nut and tighten.
9.Push knob on shaft with the tail facing down.
Timer Operating Instructions:
1.Turn knob clockwise (to the right) to desired time period. Timer will automatically turn “OFF” at the end of period.
2.Regardless of time period desired, knob must be first rotated past “TURN PAST” as indicated on timer dial. It may then be turned back to a shorter period if desired.
Timer w/Single Rocker Switch
TOP
“OFF”
POSITION
FIGURE 3