Auto-Sleep and Auto Off Functions

To prolong tip life, MFR systems with a soldering hand-piece (MFR-H1-SC, MFR-H2-ST) include an “Auto-Sleep Workstand” (WS1). When the hand-piece is placed into the workstand, the “Auto-Sleep Workstand” immediately reduces power to the hand-piece. All MFR systems have an “Auto Off” Function. The “Auto Off” Function will be engaged when the hand-piece has been idle in the sleep stand for a period of two hours. The channel LED indicator light will go from green to off. The “Auto Off” Function can be reset by cycling the power switch.

LED Indications and Meaning MFR-PS1100

MFR-PS2200

AC Power LED

Green --- Power On

Red ------ Ground Fault

Off ------- Power Off

Channel LED

Green --- On / Ready

Red ------ Open connection: tip,

connector

Off ------- Channel not selected or

channel is in Auto Off (cycle the power switch to reset)

System Specifications

 

Ambient Operating Temperature

10- 40°C

Maximum Enclosure Temperature

55°C

Input Line Voltage

100- 240 VAC, grounded circuit

Input Line Frequency

50/60 Hz

Power Consumption

 

MFR-1100

90 Watts max

MFR-2200

170 Watts max.(with both channels on)

Output Power Max.

60 Watts max. Per channel at 22°C ambient

 

temperature

Output Frequency

450--480 KHz

Power Cord 3-Wire

183cm (18/3) SJT

Dimensions w x d x h

 

MFR-1100

90mm (3.5”), 297mm (8”), 142 mm (5.6)

MFR-2200

122mm (4.8”), 200mm (8”), 152.5mm (6”)

Certification / Marking

cTUVus, CE

Tip-to-Ground Potential

<2mV

Tip-to-Ground Resistance

<2 ohms

Idle Temperature Stability

± 1.1°C in still air

Hand-piece Cable Length

L=122cm (48”), burn proof, ESD safe

Hand-piece Connector

8-pin circular DIN

Workstand Dimensions w x d x h

100 mm (4”) x 200 mm (8”) x 100 mm (4”) max