Page: 44
Service Manual for OF5800
Chapter 3 Adjustment Procedures
Bit Initial
Setting Adjustment Usage / Comments
7 0
6 1 Non-loaded cable
compensation (TX) 0:
0 db
0:
0:
4 db
1:
1:
8 db
0:
1:
12 db
1:
5 0
4 1 Non-loaded cable
compensation (RX) 0:
0 db
0:
0:
4 db
1:
1:
8 db
0:
1:
12 db
1:
3 0
2 0
1 0
0 0
Factory use only
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business