Omega DRN-PS-1000 manual Input AC Voltage / Power Output

Models: DRN-PS-1000

1 20
Download 20 pages 20.54 Kb
Page 16
Image 16

7INPUT AC VOLTAGE / POWER OUTPUT

AC INPUT CURRENT @ 100VAC INPUT

OUTPUT POWER

AC CURRENT

 

20W

338mA

 

 

21W

355mA

 

 

22W

373mA

 

 

23W

392mA

 

 

24W

412mA

 

 

MAXIMUM POWER OUTPUT

 

24W

23W

22W

21W

120V

265V

 

 

 

INPUT AC

115V

 

 

 

 

 

 

 

VOLTAGE 110V

 

 

 

 

105V

 

 

20W

 

 

 

 

 

100V

 

 

 

 

-5¼C 30¼C 35¼C 40¼C 45¼C 50¼C

 

AMBIENT TEMPERATURE ¼C

 

25¼C

 

 

 

Example: If ambient is 50¼C, maximum wattage is 21W max. for 120-265Vac. If unit is operated at 21W at an input voltage of 100V, the maximum ambient temperature allowed is 40¼C.

Figure 6.2 Ñ Temperature Derating Graph

14

Page 16
Image 16
Omega DRN-PS-1000 manual Input AC Voltage / Power Output, 20W 338mA 21W 355mA 22W 373mA 23W 392mA 24W 412mA

DRN-PS-1000 specifications

The Omega DRN-PS-1000 is a cutting-edge device designed for professionals seeking precision and efficiency in various applications. This model has quickly gained recognition for its advanced features, robust technologies, and reliable performance, making it a staple in numerous industries, including manufacturing, automation, and technology development.

One of the standout features of the Omega DRN-PS-1000 is its impressive power output. With a capability of delivering up to 1000 watts, this device ensures that it can handle demanding tasks while maintaining consistent performance. The high power output is complemented by a comprehensive range of operational modes, allowing users to customize their approach based on specific requirements.

Equipped with state-of-the-art digital control systems, the Omega DRN-PS-1000 provides unparalleled precision in managing output settings. This feature is particularly beneficial in environments where accuracy is crucial, such as laboratories and testing facilities. Users can easily adjust parameters and monitor real-time data, streamlining workflows and enhancing productivity.

The device’s rugged construction ensures durability and longevity. Designed to withstand harsh environmental conditions, the Omega DRN-PS-1000 features a robust casing that protects it from dust, moisture, and other potential hazards. This resilience makes it an ideal choice for industrial settings where equipment is subject to wear and tear.

Integration capabilities are another key characteristic of the Omega DRN-PS-1000. The device is compatible with a wide range of supporting technologies and systems, allowing for seamless incorporation into existing infrastructures. This versatility enhances its usability across different sectors, empowering professionals to achieve optimal results without the need for extensive modifications.

Safety is paramount in any high-performance device, and the Omega DRN-PS-1000 excels in this area. It includes multiple safety features, such as overcurrent protection, thermal cutoff mechanisms, and circuit isolation, ensuring that operators can work with peace of mind, knowing that they are protected from potential hazards.

In summary, the Omega DRN-PS-1000 stands out due to its powerful performance, precision control systems, rugged design, and versatile integration capabilities. These characteristics make it an invaluable asset across various applications, reaffirming Omega’s commitment to delivering quality and innovation in technology solutions.