10 Technical data

The technical data of customised versions may differ from the data in these instructions. Please observe the information specified on the type plate.

 

Type

FMG 91

 

FMG 92

 

FMG 93

 

FMG 94

 

FMG 95

 

FMG 96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measurement device characteristics

 

 

 

 

 

 

 

 

 

 

 

Flow range [GPM]

0.066…1.3

0.26…5.3

 

0.66…13.2

1.3…26.4

2.6…53

3.3…66

 

Accuracy

 

 

 

 

1% of reading

 

 

 

 

 

Repeatability

 

 

 

1%

 

 

 

 

 

 

 

Output signal

0.02

 

0.07

0.27

 

0.52

 

1.05

 

1.3

 

 

starting from [GPM]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. flow rate [GPM]

1.6

 

6.6

15.8

 

31.7

 

63.4

 

79.3

 

 

 

 

 

 

 

 

 

Response time

 

 

 

 

< 100 ms

 

 

 

 

 

Indications

 

 

red LED = Supply voltage • green LED = Flow

 

 

 

Output signal characteristics

 

 

 

 

 

 

 

 

 

 

 

Frequency output:

 

 

 

 

 

 

 

 

 

 

 

 

 

- Pulse rate / K-

 

 

 

 

 

 

 

 

 

 

 

 

 

Factor *

15000

 

3000

1500

 

750

 

380

 

300

 

 

[pulses/gal]

 

 

 

 

 

 

 

 

 

 

 

 

 

- Resolution *

0.25

 

1.0

2.5

 

5.0

 

10.0

 

12.5

 

 

[ml/pulse]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Signal shape

 

 

Square wave signal • duty cycle 50:50

 

 

 

 

 

 

 

 

can be connected as PNP or NPN open collector

 

 

 

- Signal current

 

 

 

 

≤ 25 mA

 

 

 

 

 

Electrical characteristics

 

 

 

 

 

 

 

 

 

 

 

Supply voltage

 

 

 

24 VDC ±15% or 12 VDC ±15%

 

 

 

 

 

Power consumption

 

 

 

 

0.6 W

 

 

 

 

 

 

 

Electrical protection

 

 

short-circuit proof • protected against polarity reversal

 

 

 

measures

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical connection

 

 

 

 

4-pin-plug M12x1

 

 

 

 

 

Degree of protection

 

 

IP 65 (only with a connected coupling)

 

 

 

Process variables

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium to measure

 

 

Water and other conductive liquids

 

 

 

 

 

min. conductivity of

 

 

 

 

20 μS/cm

 

 

 

 

 

the medium

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium temp.

 

 

 

 

14…140 °F (not freezing)

 

 

 

 

 

Ambient temp.

 

 

 

 

41…140 °F

 

 

 

 

 

Nominal diameter

DN 8

 

DN 15

DN 20

 

 

DN 25

 

Inner diameter

0.31 inch

 

0.55 inch

0.71 inch

0.98 inch

 

Max. working

 

 

145 psi (68 °F) • 116 psi (104 °F) • 87 psi (140 °F)

 

 

 

pressure (at …)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

higher pressure ratings on demand

 

 

 

 

 

Process connection

½ - 14 NPT

 

¾ - 14 NPT

1 - 11.5 NPT

1¼ - 11.5

 

 

 

 

 

 

 

 

 

 

 

 

 

NPT