INTRODUCTION

This instrument is a 5 digit, compact-sized portable digital thermometer de- signed to use external K type and J type thermocouple sensor. Temperature indication follows Reference Temperature/Voltage Tables (N.I.S.T. Mono- graph 175 Revised to ITS-90) for K type and J type thermocouples. Two K type thermocouple are supplied with the thermometer.

SAFETY INFORMATION

It is recommended that you read the safety and operation instructions before using the thermometer.

WARNING

To avoid electrical shock, do not use this instrument when working voltages

at the measurement surface over 24V AC or DC.

WARNING

To avoid damage or burns, do not make temperature measurement in mi-

crowave ovens.

CAUTION

Repeated sharp flexing can break the thermocouple leads. To prolong lead

life, avoid sharp bends in the leads, especially near the connector.

Input Connector:

Accepts standard miniature thermocouple connectors (flat blades spaced 7.9mm, center to center).

ENVIRONMENTAL

Ambient Operating Ranges:

0°C to 50°C (32°F to 122°F) <70% R.H.

Storage Temperature:

-20°C to 60°C (-4°F to 140°F) <80% R.H.

GENERAL

Display: 5 digit liquid crystal display (LCD).

Overload: “----.-“ or “OL” is display.

Battery: 1.5V x 4 PCS (SIZE AAA) UM-4 R03.

Battery Life: 200 hours typical with carbon zinc battery.

Auto power off: 30 minutes, press power key to resume operation.

Dimensions: 160mm(H) x 83mm(W) x 38mm(D)

Weight: Approx. 265g including batteries.

Supplied Thermocouples (1 per input):

1 meter (40”) type K insulated beaded wire thermocouple. Maximum insula- tion temperature is 482°C (900°F). Thermocouple accuracy is ±1.1°C or 0.4% of reading (whichever is greater) from 0°C to 1250°C.

SPECIFICATIONS

ELECTRICAL

Temperature Scale: Celsius or Fahrenheit user selectable.

Measurement Range:

J-TYPE -200°C to 1050°C, (-328°F to 1922°F) K-TYPE -200°C to 1370°C, (-328°F to 2498°F)

Resolution: 0.1°C or 0.2°F

Accuracy: Accuracy is specified for operating temperatures over the range of 18°C to 28°C (64°F to 82°F), for 1 year, not including thermocouple error. ±(0.05% rdg + 0.3°C) -50°C to 1370°C

±(0.05% rdg + 0.7°C) -50°C to -200°C

±(0.05% rdg + 0.6°F) -58°F to 2498°F ±(0.05% rdg + 1.4°F) -58°F to -328°F

Temperature Coefficient:

0.1times the applicable accuracy specification per °C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to122°F).

Input Protection:

24V dc or 24V ac rms maximum input voltage on any combination of input pins.

Maximum Differential Common Mode Voltage (Maximum Voltage be- tween T1 and T2 during measurement): 1volt.

Reading Rate: 1 sample/second.

OPERATING INSTRUCTIONS

1. Power Switch

The key turns the thermometer on or off. In the SET mode the unit can- not be powered off. Exit SET mode to power off.

APO function mode

Press power key for more than 6 seconds to disable the auto-power function. The display will show “APO OFF”.

2.°C/°F Selecting the Temperature Scale

Readings are displayed in either degrees Celsius(°C) or degrees Fahren- heit(°F). When the thermometer is turned on, it is set to the temperature scale that was in use when the thermometer was last turned off. To change the temperature scale, press the °C/°F key.

3.Button (only Main display)

Press this key to enter the Data Hold mode, the “HOLD” annunciator is dis- played. When HOLD mode is selected, the thermometer holds the present

readings and stops all further measurements. Press the key again to cancel HOLD mode and resume measurement. In the MIN/MAX recording

mode, press

key to stop the recording. Press

key again to resume

recording. (Previously recorded readings are not erased).

Backlight function mode

 

Press the

button for more than two seconds to turn on the backlight

Press the button again for more than two seconds to turn off the backlight. The backlight will switch-off automatically after 30 seconds.

4.T1 T2/T1-T2 Main Display Input Selection

The input selection determines which input is selected for the main display; T1 thermocouple, T2 thermocouple or the difference between the two ther- mocouples (T1-T2), when the thermometer is turned on it is set to T1.

5.K/J T1 Input Type Selection (Main display)

The K/J key selects the T1 thermocouple type, when the main display is showing T1. When the thermometer is turned on, it is set to the type se- lected when the thermometer was last turned off.

6.MIN MAX with Elapsed Time Mode (only Main display)

Press MIN MAX key to enter the MIN MAX Recording mode, (displays the Maximum reading with time, Minimum reading with time and Average reading stored in record mode). In the this mode the automatic power-off

feature is disabled and key, °C/°F key, REL key, SET key, Hi/Lo Limits key and main display T1 T2 T1-T2 key, K/J key are disabled. The beeper emits a tone when a new minimum or maximum value is recorded.

Page 1
Image 1
Omega Engineering operating instructions Model HH802U, Introduction, Safety Information, Environmental, General

HH802U specifications

The Omega Engineering HH802U is a versatile handheld thermometer designed for precise temperature measurement in various environments. This device is especially favored by engineers, HVAC technicians, and laboratory personnel for its accuracy, user-friendly interface, and robust design.

One of the standout features of the HH802U is its dual-channel capability. This enables users to connect two different temperature probes simultaneously, allowing for comparative measurements or the monitoring of multiple temperature points at once. This feature is particularly useful in applications like HVAC testing, where monitoring air temperature at different points is essential for system assessment and troubleshooting.

The HH802U supports a wide range of temperature probes, including thermocouples and RTDs (Resistance Temperature Detectors), giving users the flexibility to select the best sensor for their specific application. The device is compatible with several types of thermocouples such as Type J, K, T, and E, making it adaptable for various industrial and laboratory settings.

Another important characteristic of the HH802U is its impressive measurement range. The device can measure temperatures from -200°C to 1372°C, depending on the connected probe. This wide range ensures that it can handle both very low and high-temperature applications, from cryogenics to industrial processes.

The HH802U's display is equipped with a large, easy-to-read LCD screen, which shows both channels’ temperatures simultaneously, aiding users in quick data evaluation. Additionally, the device features data logging capabilities, allowing users to store temperature readings for later analysis. With its built-in memory, users can record up to 100 readings, facilitating adjustment and review over time.

The instrument also boasts a user-friendly interface, including simple controls and a menu, making it easy for even novice users to navigate through functions and settings. Its compact and lightweight design makes it portable, suitable for fieldwork, and it comes with a protective rubber boot to enhance durability.

With a battery life that supports prolonged operation, the HH802U is ideal for demanding environments where power sources may be limited. Overall, the Omega Engineering HH802U combines advanced technology, versatility, and ease of use, making it a valuable tool for professionals requiring accurate temperature measurements in a variety of applications.