Specifications 5

SECTION 5 – SPECIFICATIONS

5.1 - General

Temperature Range:

 

OS136-1

-18 to 204ºC (0 to 400ºF)

OS136-2

149 to 538ºC (300 to 1000ºF)

Accuracy: @22ºC (72ºF) ambient

 

OS136-1

3% of Rdg or 4.4ºC (8ºF) whichever is greater

OS136-2

3% of Rdg or 5.5ºC (10ºF) whichever is greater

 

From 185 to 510ºC (365 to 950ºF)

Repeatability:

Optical Field of View:

Spectral Response:

Response Time:

Emissivity:

Analog output:

MA

V1

V2

K

MVC

MVF

Output Load Requirements:

Min. Load (0 to 5 Vdc)

Min. Load (0 to 10 Vdc)

Max. Load (4 to 20 mA)

Min. Load (10 mV/Deg)

Min. Load (K T/C)

Operating Ambient Temperature:

No Water Cooling

With Water Cooling (OS136-WC) With Air Cooling (OS136-WC)

Operating Relative Humidity: Water Flow Rate for OS136-WC: Air Flow Rate for OS136-WC Warm up Period:

Thermal Shock:

1% of Rdg.

6 to 1 (Distance to Spot Size)

5 to 14 microns

150 msec, 0 to 63% of final value

Fixed at 0.95

4 to 20 mA

0 to 5 Vdc

0 to 10 Vdc

K type Thermocouple, compensated

10mV/ºC

10mV/ºF

1K-Ohms

2K-Ohms

(Power Supply – 4) / 20 mA

10K-Ohms

100K-Ohms

0 to 70ºC (32 to 158ºF)

0 to 200ºC (32 to 392ºF)

0 to 110°C (32 to 230°F)

Less than 95% RH, non-condensing

0.25GPM, room temperature, minimum 5 CFM (2.4 liters/sec)

1 to 2 minutes

About 30 minutes for 25ºC abrupt ambient temperature change

Air Flow Rate for Air Purge Collar

1 CFM (0.5 liters/sec.)

Transmitter Housing:

Stainless Steel 316, NEMA-4 & IP65 rated

Power:

12 to 24 VDC @ 50 mA

Dimensions:

19 OD x 89 L mm (0.75" OD x 3.5" L)

Weight:

0.40 lb (181 g)

8