OS562 Thermometer Operating Instructions
STORAGE & CLEANING
This thermometer is a
Default Screen
Simply aim the thermometer at the measure target
with Lens 7 and press Meas. key 9 to display
the surface temperature.
The Distance:Spot is 11:1. Please make sure the
target area is within the field of view.
Laser Warning |
|
and Certification | Laser Aperture |
Label |
The thermometer should be stored at room temperature between
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times. Care should be
taken when cleaning the lens; use only a soft cloth or cotton swab moistened with water or medical alcohol. Allow the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
|
| ‘Hi’ or ‘Lo’ is displayed when the temperature being measured is outside of the settings of HAL and LAL. |
|
| ‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient |
|
| temperature. ‘Er3’ is displayed when the ambient temperature exceeds 0°C (32°F) or |
|
| 50°C (122°F). The thermometer should be allowed plenty of time (minimum 30 minutes) |
_ | _ _ | _ to stablize to the working/room temperature. |
For all other error messages, it is necessary to reset the thermometer. To reset it, turn the instrument off, remove the batteries and wait for a minimum of one minute, reinsert the batteries and turn the instrument on. If the error message remains, please contact the Customer Service department for further assistance:
FUNCTION |
| Emissivity key is inset. | |
Press Emissivity key 1 | for setting the emissivity. Need blunt pointed object to use. | ||
|
|
|
|
| Press Emissivity key 1 , then press Up key 4 or Down key 2 to set the emissivity, then press | ||
| Mode key | 5 to confirm it. The emissivity can be changed from 0.10 (10E) to 1 (100E). |
Press Mode key 5 for scrolling more display functions as follows.
The emissivity data will show here. (The default emissivity is 0.95.)
Press Mode key 5 for the Maximum (MAX), Minimum (MIN), Difference between MAX and
MIN (DIF) and Average (AVG) modes. During the measurement, the special modes reading will be displayed beside the mode icon.
Press Up key 4 | or Down key 2 to change the High Alarm (HAL) or Lo Alarm (LAL), then |
press Meas. key | 9 to confirm it. For example: When the reading is 27°C with an LAL of 27.1°C, the |
Low icon will flash and you will hear a beep.
Connect the thermocouple with Thermocouple socket 10 and put the probe in/on the target. The thermometer will display the temperature automatically, without your needing to press any button. To see the minimum or maximum data during the probe measurement, hold down the Up key 4
or Down key 2 .
After measuring high temps, the probe may remain HOT for while.
The thermomet er will automatically shut off if left idle for more than 60 sec, unless in PRB mode. (In PRB mode, it will shut off if left idle for more than 12 minutes.)
ADD VALUE
In MAX, MIN, DIF, | Press Up key | 4 | for LOCK mode ON/OFF. The lock mode is | particularly useful for | |||||
AVG mode: | continuous monitoring of temperatures for up to 60 minutes. |
|
|
| |||||
|
| Press Down key | 2 | for oC or oF switching. |
|
|
| ||
|
|
|
|
|
|
|
| ||
In all modes: First | and press Up key | 4 | for backlight function |
|
|
| |||
hold down the Meas. | ON/OFF. |
|
|
|
|
|
|
| |
key 9 |
|
|
|
|
|
|
|
| |
and press Down key 2 | for laser function ON/OFF. |
|
|
|
| ||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| AVOID EXPOSURE. | |
|
|
|
|
|
|
|
| LASER RADIATION | |
| CAUTION You may receve harmful laser radiation exposure if you do not adhere to the warnings listed below: | IS EMITTED FROM THIS APERTURE | |||||||
|
| CAUTION |
| ||||||
1. | Use of controls or adjustments or performance of procedures other than those specified here may |
|
| ||||||
| LASER RADIATION | ||||||||
| result in hazardous radiation exposure. |
|
|
|
|
| |||
|
|
|
|
|
| DO NOT STARE INTO BEAM | |||
2. | Do not look at the laser beam coming out of the lens or view directly with optical instruments - eye |
|
|
| |||||
|
|
| |||||||
| damage can result. |
|
|
|
|
|
| OUTPUT<1mW, | |
|
|
|
|
|
|
| WAVELENGTH | ||
3. | Use extreme caution when operating the laser sighting. |
| |||||||
| CLASS II (2) LASER PRODUCT. | ||||||||
4. | Never point the laser beam at a person. |
|
|
|
|
| COMPLIES WITH | ||
5. | Do not attempt to open the thermometer. There are no user serviceable parts inside. |
| FDA 21CFR 1040.10 | ||||||
| & EN | ||||||||
6. | Keep out of reach of all children. |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
BATTERIES The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements | ‘Battery Low’: batteries need to be | ‘Battery Exhausted’: measurements |
are possible | replaced; measurements are still possible | are not possible |
When the ‘Low Battery’ icon indicates the batteries are low, the batteries should be replaced immediately with AAA,
1.5V batteries. Please note: It is imp ortant to turn the instrument off before replacing the batteries; otherwise the thermometer may malfunction.
Dispose of used batteries promptly and keep away from children.
SPECIFICATIONS
Item | Thermocouple probe Scan function | ||||||
(K type probe not included) | |||||||
|
|
|
|
|
| ||
Measurement Range | |||||||
Operating Range | 0 to 50°C (32 to 122°F) |
| |||||
Accuracy | ±1.0°C (1.8°F) | 2% reading or 2°C (4°F) | |||||
(Tobj=15~35°C, Tamb=25°C) | at 20 to 26°C (68 to 78°F) ambient | ||||||
|
|
|
|
| |||
Accuracy |
|
| ±2% of reading or 2°C (4°F), |
|
|
| |
Tamb=23±3°C) | whichever is greater |
| |||||
Resolution |
| 0.1°C/0.1°F |
| ||||
Response Time (90%) | 1 sec |
| |||||
Distance:Spot | 11:1 |
|
|
| |||
Laser Power Output | <1mW |
| |||||
Wavelength | 630~ 670 nm, Red |
| |||||
Laser Classification | Class 2, |
| |||||
Beam Diameter | 5mm |
| |||||
Beam Divergence | <2mrad |
| |||||
Laser Power Switch |
|
| 2 key |
| |||
Battery Life | Typ. 14 hours 18 min. continuous use (Alkaline, without Laser and Backlight.) | ||||||
Dimensions | 175.2 x 39.0 x 71.9 mm (6.9 x 1.53 x 2.8 in) |
| |||||
Weight | 179 grams (6.3 oz) including batteries (AAA 2 pcs) |
Note: Under an electromagnetic field of 3 V/m from 200 to 600 MHz, the maximum error is 10°C (18°F).
Caution: The measure range is for thermometer only. User should choose proper probre types for different kinds of applications. Please make sure the target to be measured will not exceed the temperature range of the probe to avoid permanent damage of the thermocouple probe.
EMC/RFI
Read ings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
PATENT NOTICE: U.S. PAT. B1 5,368,392; 5,524,984; 5,727,880; 5,823,678; 5,823,679; 6,123,453; 6,267,500 B1; 6,341,891 B1; 6,377,400 B1; 6,540,398 B2; 6,614,830 B1; 6,633,434 B2; 6,659,639; 6,901,089 B1 / Canada 2,114,806; 2,317,734 / France
2 756 920; 2 767 921; 2 773 213; 2 773 214 / Germany G 94 22 197.9; G 94 22 203.7 / Holland 1007752 / U.K. Registered 2,237,493; 2,320,324; 9726133.3 / EPO 0 644,408 B2; EPO 1085 307 A1. Other U.S. and Foreign Patents Pending.