4.4Adjustments

Should the calibration of the rain gauge appear to be incorrect and in need of adjustment, change the heights of the two calibration posts adjustment screws. To change the screw heights, loosen the nut on the top of the post that locks the screw into place. Rotate each screw by a small amount only and recheck the calibration for the new screw positions. Empty all water from the buckets but do not dry off the buckets. The exact amount of water needed for a single bucket tip may be added into a bucket to see how closely the calibration post screw may be to the position needed for the bucket to tip. After obtaining this point of adjustment, tighten down the locking nuts on the calibration posts screws and test the gauge using a large amount of water at the proper flow rate and count the total number of tips.

The calibration post screws should be adjusted upward whenever the amount of water needed to cause the bucket to tip is more than the amount shown in the calibration table. Whenever less water than the amount in the table causes the bucket to tip, the screws need to be adjusted downward. The two sides of the bucket assembly should generally be at about the same calibration adjustment. There may be situations where one of the bucket calibration post screws has moved and is off more than the other screw. In this situation the single tip amount of water calibration method may be better for correcting the one side of the bucket to match the other side more closely. Do not dry the buckets during the adjustment procedure.

Carefully tighten the locking nuts on the calibration post screws after completing the adjustments. Recheck the calibration to ensure that the screws have not shifted as the nuts were tightened.

Chapter 5: Maintenance

Annual maintenance of the rain gauge is recommended. Cleaning of the gauge more often may be necessary in areas where there is a lot of leaves, dust, and other debris that falls into the gauge. Cleaning includes removal of the outer cover, rinsing and drying off of the buckets, cleaning of the drain holes, and removal of debris from all of the screens. the outer and inner funnels should also be rinsed and dried off to remove dirt, dust and insects.

The gauge calibration should be tested during the maintenance procedure and adjusted if necessary. If there is a regularly scheduled maintenance of the gauge on a monthly basis, the calibration can be tested less often.

At least once a year, or if possible, after six months of heavy operation, a drop of light machine oil should be placed onto the bearings. Do not over-oil and wipe off any excess oil.

The electrical output of the gauge should be tested to ensure that the magnet and switch assemblies are still functioning. The switch used in the gauge is a momentary contact, normally open, single pole switch. Test the switch using an ohmmeter, buzzer, or counter, or

5

Page 11
Image 11
Omega Engineering RG-2500 manual Adjustments, Maintenance

RG-2500 specifications

The Omega Engineering RG-2500 is an advanced temperature and process measurement device designed for industrial applications. Known for its precision and reliability, the RG-2500 stands out in the realm of industrial sensors and controllers. This state-of-the-art instrument is tailored to meet the demands of various industries, including food processing, pharmaceuticals, and semiconductor manufacturing.

One of the main features of the RG-2500 is its wide temperature range capability, enabling users to monitor processes spanning from cryogenic temperatures to extremely high levels. This adaptability makes it ideal for diverse applications. Coupled with its high accuracy and linearity, it ensures that temperature readings are not only precise but also consistent throughout various conditions.

The RG-2500 integrates advanced sensing technologies that provide rapid response times, crucial for dynamic industrial environments where process control is essential. Its digital signal processing capabilities enhance the resolution of measurements and minimize noise, resulting in more reliable data acquisition. This system also supports diverse input types, including thermocouples, RTDs, and analog signals, making it versatile across a multitude of setups.

Another significant characteristic of the RG-2500 is its robust construction. Built to withstand harsh industrial environments, it features protective housing made from durable materials to resist moisture, dust, and physical impact. Furthermore, the RG-2500 employs advanced thermal insulation technology, ensuring that the sensor remains unaffected by external temperature fluctuations that could otherwise skew readings.

User accessibility is enhanced through an intuitive interface, providing easy navigation for operators and technicians. The display offers clear readouts and enables simple configuration of measurement parameters, alarm settings, and logging options. The RG-2500 also boasts connectivity features that facilitate seamless integration with existing data acquisition systems and control networks, including Ethernet and RS-485 interfaces.

The Omega Engineering RG-2500, with its advanced features, reliability, and versatility, serves as an essential tool in modern industrial process management, allowing businesses to achieve greater efficiency and control over their operations. Its commitment to innovation ensures that it continues to meet the evolving needs of various sectors, solidifying its reputation as a leader in temperature measurement technology.