Specifications
Repeatability: ±(1% rdg + 1 digit)
Resolution: 1°C or 1°F (0.1°C or °F on OS530HR)
Response Time: 250 msec
Spectral Response: 8 to 14 ∝
Emissivity: 0.10 to 1.00 in 0.01 increments
Operating Ambient: 0 to 50°C (32 to 122°F)
Power: 4 “AA” alkaline batteries (2 sets included) or optional ac adaptor Battery Life: 60 hr, alkaline;
10 days, lithium
Analog Output: 1 mV/°C or 1 mV/°F
Tripod Mount: 1⁄4" to 20 UNC
Display: Backlit LCD; displays current and min or max, differential, average temperatures simultaneously Alarm: High alarm standard,
TM
Now Available!
PATENTED
Covered by U.S and
International patents and
pending applications
Consult Sales and Engineering for Additional Information at
Laser Sight Specifications
with audible and visual indication
Wavelength (color): 650 nm (red)
Operating Distance:
Laser Dot: 0.6 to 12 m (2 to 40')
Laser Circle: 0.6 to 4.5 m (2 to 15') FDA Classification: Class II European Classification: Class 2 Beam Diameter: 5 mm
Operating Temperature:
0 to 50°C (32 to 122°F)
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model Number | OS530L | OS530HR | OS532 | OS533RS | OS534DL | |||
Price | $295 | $345 | $345 | $550 | $695 | $650 | $750 | $750 |
Accuracy* | ±1% rdg | ±1% rdg | ±1% rdg | ±1% rdg | ±1% rdg | ±1% rdg | ±1% rdg | ±1% rdg |
Range | ||||||||
| 0 to 1000°F | 0 to 1000°F | 0 to 1000°F | 0 to 1000°F | 0 to 1000°F | 0 to 1600°F | 0 to 1600°F | |
Emissivity | adjustable | adjustable | adjustable | adjustable | adjustable | adjustable | adjustable | adjustable |
Backlit Dual Display | std | std | std | std | std | std | std | std |
Distance to Spot Size Ratio | 10:1 | 20:1 | 0.15"@6" | 10:1 | 0.15"@6" | 20:1 | 0.15"@6" | 30:1 |
Differential Temperature | std | std | std | std | std | std | std | std |
Min/Max Temperature | std | std | std | std | std | std | std | std |
Average Temperature | std | std | std | std | std | std | std | std |
High Alarm | std | std | std | std | std | std | std | std |
Low Alarm | — | — | — | — | std | std | std | std |
Audible Buzzer & Indicator | std | std | std | std | std | std | std | std |
Ambient Target Temp Comp. | — | — | — | — | std | std | std | std |
Analog Output | 1 mV/deg | 1 mV/deg | 1 mV/deg | 1 mV/deg | 1 mV/deg | 1 mV/deg | 1 mV/deg | 1 mV/deg |
— | — | — | — | std | std | std | std | |
Thermocouple Input | — | — | — | std | std | std | std | std |
Data Storage | — | — | — | — | — | — | std | std |
Laser Sight | dot/circle | dot/circle | dot | dot/circle | dot | dot/circle | dot | dot/circle |
Trigger Lock | std | std | std | std | std | std | std | std |
Last Temperature Recall | std | std | std | std | std | std | std | std |
Distance Measuring | optional | optional | — | optional | — | optional | — | optional |
*or 1.7°C (3°F), whichever is greater. Model OS530HR has 0.1° display resolution.
Ordering Examples: OS532, handheld infrared thermometer with
Accessories
Model No. | Price | Description |
|
|
|
|
|
| |||
$25 | 110 Vac wall adaptor |
|
|
| |
$25 | 220 Vac wall adaptor |
|
|
| |
| 30 | Hard carrying case |
|
|
|
15 | Soft carrying case (spare) |
|
|
| |
88013K | 110 | Surface probe, up to 815°C (1500°F) |
|
|
|
88001K | 110 | Surface probe, up to 482°C (900°F) |
|
|
|
125 | NIST Traceable Calibration |
|
|
| |
|
| ||||
TRIPOD | 45 | Lightweight tripod with carrying case |
| Lightweight tripod | |
|
|
|
| measuring meter | with carrying case sold |
75 | Distance measuring meter with mounting bracket |
| |||
| sold separately, $75 | separately, $45 | |||
|
|
|
| ||
|
|
|
|
J