DMD-480-S2 SERIES AC POWERED BRIDGESENSOR - RS232 INTERFACE
8
PHONE:(203)359-1660 FAX:(203)359-7700
1-800-TC OMEGA
info@omega.com
SOLVING EQUATION A - EQUATION B
A = (100 ÷ 40,245) = .00248478
SOLVING FOR C, C = -1,500 x .00248478, C = -3.727
VERIFY YOUR RESULTS BY PLACING YOUR SOLUTIONS BACK INTO
EQUATIONS A AND B:
A) (41,745 x 0.00248478) + (-3.727) = 100.000 LBS
B) (1,500 x 0.00248478) + (-3.727) = 0.000 LBS
ONE COUNT = .00248 POUNDS
G. WRITING DATA TO A FILE
UNDER OPTION 3 OF THE SETUP MENU, THE COLLECTED DATA MAY BE
WRITTEN TO A FILE SELECTED BY THE USER. THE USER MUST GIVE A FILE NAME
AND A PATH, (DRIVE:\PATH\FILE). THE DATA RECORDED IN THE FILE IS
RECORDED IN THE FOLLOWING MANNER: UNIT NUMBER (ADDRESS), DATE, TIME,
UNSCALED READING, AND THE SCALED READING. AN EXAMPLE OF A FILE’S
CONTENTS IS SHOWN BELOW.
1 , “07-30-1993” , “09:30” , 30003 , 10.0000
2 , “07-30-1993” , “09:30” , 15000 , 5.00190
3 , “07-30-1993” , “09:30” , 00015 , 0.00999
1 , “07-30-1993” , “09:31” , 30003 , 10.0000
2 , “07-30-1993” , “09:31” , 10000 , 3.33633
3 , “07-30-1993” , “09:31” , 00100 , 0.03831
NOTICE THAT THE DATA IS DELIMITED BY COMMAS AND QUOTE MARKS, WHICH
IS A STANDARD METHOD FOR WRITING TO FILES SO THAT ANY POPULAR
SPREADSHEET AND DATABASE PROGRAM CAN READ THE COLLECTED DATA. A
DISK THAT IS COLLECTING DATA INTO A FILE WILL CONTINUE TO COLLECT DATA
UNTIL IT IS FILLED UP, AT WHICH TIME AN ERROR MESSAGE WILLAPPEAR
INDICATING THE DISK IS FULL.
C4500.BAS V2.1 December 21, 1994
M-3281