Management Options iConverter, Serial Agent

Network Management

1:Chassis and Module Management

2:Set Module Name Preferences Management Module Preferences

3:IP and Control Preferences

4:SNMP Preferences

5:Abandon Preference Changes

6:Save Preference Changes

7:Restore Factory Defaults

8:Restart Management Module

9:Other Networking Features Management Module Maintenance

10:Firmware Update

11:Set Date/Time

IP Address = 192.168.1.220

Chassis Number = 1

Enter Choice, <H>elp, E<x>it >

Figure D: Command Line Interface Menu Options

The CLI interface allows for the detailed configuration of the module. It is recommended to configure the module with an IP address associated with the attached network. Also, SNMP traphost address should be configured if the module is managed with an SNMP-based Management System. See the 2FXM User Manual for complete information.

iConverter 2FXM Plug-in Module QUICK START GUIDE

The Omnitron iConverter® 2FXM Network Interface Device (NID) with integrated management provides Fast Ethernet (100BASE-FX) fiber-to-fiber media conversion.

The 2FXM conforms to Ethernet in the First Mile (EFM) fiber standards to support Fiber-to-the-X (FTTX) Metropolitan and Enterprise LAN networks. Built-in Operation, Administration and Maintenance (OAM) functionality enables the 2FXM to operate as a managed demarcation point at the customer premises and network edge, offering service provisioning functions, such as Quality of Service and Bandwidth Control (rate-limiting) capabilities.

The 2FXM module can be managed using Omnitron’s NetOutlookTM SNMP Management Software, 3rd Party SNMP Client, Telnet or the Command Line Interface (CLI).

For more information, including the complete User Manual on the 2FXM Plug-in module, access Omnitron’s documentation download web page to view all relevant documents:

http://www.omnitron-systems.com/downloads.php

INSTALLATION PROCEDURE

1)Configure DIP-Switches

2)Install Module in Chassis and Connect Cables

3)Configure Module via Command Line Interface

4)Verify Operation

1) CONFIGURE DIP-SWITCHES

4) VERIFY OPERATION

Once the module has been installed and configured per steps 1 - 3, verify the module is operational by viewing the LED indicators.

The Power LED indicates the module is receiving power from the chassis.

The Fiber Optic link LEDs indicate the fiber optic connections have been established. Verify the Link Mode selection is set to Link Segment (LS). Until a stable

LED Function

Color

Off State

On / Blinking State

"Legend"

 

 

 

 

 

 

 

Power "Pwr"

Amber

No power

On: Module has power

 

 

 

On: Power available from

Power Supply Status

Amber

Chassis Power

installed Power Supply #X

#X

Supply not installed

Blinking: No power available

 

 

 

from installed Power Supply #X

Port 1

 

 

On: Fiber link is active

Fiber Link Activity

Green

No Fiber Link

Blinking: Fiber Data Activity

"P1"

 

 

 

 

 

Port 1

 

 

 

Half/Full Duplex

Green

Half-Duplex

On: Full-Duplex

"FDX"

 

 

 

Chassis Management

 

Chassis Slave

On: Chassis Master

Master/Slave

Green

Blinking: Operating in OAM

Mode

"Msr/Slv"

 

 

Mode

Port 2

 

 

On: Fiber link is active

Fiber Link Activity

Green

No Fiber Link

Blinking: Fiber Data Activity

"P2"

 

 

 

 

 

Port 2

 

 

 

Half/Full Duplex

Green

Half-Duplex

On: Full-Duplex

"FDX"

 

 

 

DIP-SWITCH BANK 1

SW1 - PAUSE ENABLE

When the Pause Enable DIP-switch is in the LEFT “Off” position (factory default), the 2FXM disables the fiber ports’ ability to send and receive Pause frames during network congestion. Setting this DIP-switch to the RIGHT “On” position, enables the 2FXM to receive Pause frames from its link partner. This enables the 2FXM to stop transmitting traffic to its link partner and store incoming frames from the other port in the internal buffer until the congestion clears. If the internal buffer of the 2FXM becomes congested, it will transmit a Pause frame to its link partner.

Switch 1

Bank 2

Switch 8

Switch 1

Bank 1

Switch 8

LEFT

RIGHT

Figure A: DIP-Switch Locations

link is established, leave the

Figure E: LED Indicators

Link Mode configured for LS.

 

After a Link presence is established, the Link Mode selection can be modified.

Form 040-08940-002 D 12/07

SW2 - FIBER PORT 1 FULL/HALF DUPLEX

Setting this DIP-switch to Half-Duplex “HDX”facilitates a connection that supports Half- Duplex. Setting this DIP-switch to Full-Duplex “FDX” facilitates a connection that supports Full-Duplex operation.

Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618

949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com

Page 1
Image 1
Omnitron Systems Technology iConverter 2FXM quick start Installation Procedure, Configure DIP-SWITCHES, Verify Operation