Enhanced Series
For personal computers and work stations
ES550C / ES800C / ES1000C /
ES550C / ES800C / ES1000C / ES1500C | * ES1500C |
Protection for small electronic equipment
The ESC series offer the highest power capacity and the best equipment protection around. Not only do they protect against blackouts, sags and surges, but with the added feature of AVR (Automatic Voltage Regulator), these UPS products ensure that only clean and safe currents reach your equipment.
What is AVR?
AVR is a feature that corrects under and over voltages without draining the battery, thus providing extended battery life and, most important, allowing the UPS to provide high quality power during unacceptable voltage fluctuations.
Features |
| Backup Time (Typical) | ||
* AVR (automatic voltage regulator) | * Easy battery replacement procedure | ES550C | 1PC+1LCD 21 mins | |
* Up to 8 battery backup outlets | * 1050 Joules surge energy rating | ES800C | 1PC+1LCD 33 mins | |
* RJ11/RJ45 protection | * 4 hours battery recharge time | ES1000C1PC+1LCD | 40 mins | |
| * Smart power management software | ES1500C1PC+1LCD | 45 mins |
Series
Standby UPS
Line Interactive UPS Series |
Series
Series On Line UPS
Front Panel
ES550C / ES800C
A |
| B |
| C | D | ||||
Battery | Battery |
| AC | ON/OFF | |||||
Fault | Mode | Mode | TEST/SILENCE | ||||||
|
|
|
|
|
|
|
|
|
|
A)Battery Fault C) AC Mode
B)Battery Mode D) On / Off, Test / Silence
ES1000C / ES1500C
A | B | C | D |
| E | F | |||||||||
Battery |
|
|
| Battery |
|
|
|
|
|
| ON/OFF | ||||
Fault | Buck | Mode | Boost | AC Mode | TEST/SILENCE | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A) Battery Fault | D) Boost |
B) Buck | E) AC Mode |
C) Battery Mode | F) On / Off, Test / Silence |
Rear Panel
ES550C / ES800C
Communication
Port
Data Line
Protection
|
|
|
| Battery Backup |
|
|
|
| ||||
|
|
| ||||||||||
|
|
|
| Outlets |
|
|
|
|
|
|
|
|
|
|
|
| Convenience |
|
|
| |||||
|
|
|
| Outlets |
|
|
|
|
|
|
|
|
|
| Surge Protected |
|
|
|
| ||||||
100V | Outlets | Input |
|
|
|
|
|
| ||||
|
|
|
|
|
| |||||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| 220V | ||||
110V |
|
|
|
|
|
|
|
| 230V | |||
120V |
|
|
|
|
|
|
|
| 240V |
ES1000C / 1500C
Communication
Port
Data Line
Protection
|
|
|
| Output |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| Breaker |
|
|
|
|
| ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| ||||||
|
|
|
| Input |
|
|
|
|
|
| |
100V |
|
|
|
|
|
| 220V | ||||
|
|
|
|
|
|
| |||||
110V |
|
|
|
|
|
|
| 230V | |||
120V |
|
|
|
|
|
|
| 240V |
Specifications
| Model Name |
| ES550C | ES800C | ES1000C | ES1500C |
| |
| Topology |
|
|
|
| |||
|
|
| Simulated Sine Wave |
|
| |||
| INPUT |
|
|
|
|
|
|
|
| Maximum Capacity |
| 550VA / 330W | 800VA / 480W |
| 1000VA / 700W | 1400VA / 980W |
|
| Nominal Input Voltage |
|
| 100 / 110 / 120Vac or 220 / 230 / 240Vac** |
|
| ||
| Nominal Input Frequency |
|
| 50Hz / 60Hz Auto Sensing |
|
| ||
| Input Voltage Range |
|
| Rated Voltage +/- 25% |
|
| ||
| Input Short Protection |
| Circuit Breaker (US), Fuse (IEC) |
| Circuit Breaker |
| ||
| OUTPUT |
|
|
|
|
|
|
|
| Nominal Output Voltage |
|
| 100 / 110 / 120Vac or 220 / 230 / 240Vac** |
|
| ||
| Output Voltage Regulation |
|
| Rated Voltage +/- 5% (on battery) |
|
| ||
| Transfer Time |
|
| 4 ms (typical) |
|
| ||
| Number of Outlets |
| 3 UPS outlets + 3 Surge protected outlets (US) |
| 8 Battery backup (US) |
| ||
|
|
| 3 UPS outlets + 2 Surge protected outlets (IEC) |
| 8 Battery backup (IEC) |
| ||
| PROTECTION |
|
|
|
|
|
|
|
| Automatic Voltage Regulation (AVR) |
| Yes |
|
|
| ||
| Data Line Surge Protection |
|
| RJ11 / RJ45 |
|
| ||
| Surge Energy Rating |
|
| 1050 Joules |
|
| ||
| Normal Mode Noise Suppression |
| Full time EMI/RFI filtering |
|
| |||
| BATTERY |
|
|
|
|
|
|
|
| User Replaceable Battery |
| 12V/7.2AH x 1 | 12V/34W x 1 |
| 12V/7.2AH x 2 | 12V/34W x 2 |
|
| Recharge Time to 90% |
|
| < 4 | Hours |
|
| |
| Audible Alarms |
|
| Battery mode / UPS fault / Overload |
|
| ||
| COMMUNICATION INTERFACE |
| RS232 |
|
|
| ||
| Communication Port* |
|
|
|
|
| ||
| ENVIRONMENTAL |
|
|
|
|
|
|
|
| Operation Temperature |
|
| 0°~40°C / 32°~104°F |
|
| ||
| Storage Temperature |
|
|
|
| |||
| Audible Noise |
|
| < 40 dBA |
|
| ||
| PHYSICAL |
|
|
|
|
|
|
|
| Dimensions (Physical / Packing) | (in) | 12.7 x 4 x 6.5 / 16.1 x 7.7 x 10.6 |
| 14.9 x 5.5 x 7.9 / 19.2 x 10.6 x 12.8 |
| ||
| (L x W x H) | (mm) | 322 x 102 x 165 / 410 x 195 x 268 |
| 378 x 140 x 201 / 487 x 270 x 326 |
| ||
| Weight (Net / Gross) | (lbs) | 14.1 / 16.1 | 15.4 / 17.4 |
| 31.1 / 33.3 | 35.7 / 39.2 |
|
|
| (kg) | 6.4 / 7.3 | 7 / 7.9 |
| 14.1 / 15.7 | 16.2 / 17.8 |
|
| CONFORMANCE |
|
|
|
|
|
|
|
| Approvals |
|
| BSMI ; CE ; UL / cUL ; |
|
|
Specifications are subject to change without notice.
*You can purchase RS232 to USB cable.
**See VS1000C on page 6
Win |
| IBM |
|
|
|
windows | windows | IBM OS/2 | Novell Netware | SUN Solaris | Simulated |
95/98 | 2000 / XP | IBM AIX | Linux | ||
ME/NT | 2003 / Vista | FreeBSD | SGI Irix | Sine Wave |
11.