Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner
Codabar Settings (continued)
ZZ Start/End
Program
Menu [[
HA
Enable
Codabar
normal mode
only IB
%
HB Min. data
3 chars. IC
HC Min. data
1 char. ID
HD Enable space
insertion IE
HE Disable space
insertion IF
%
HF Min. data
5 chars. IG
%
HH Enable
interchar. gap
check II
%
HI Disable
interchar. gap
check IJ
Codabar Settings
Codabar (NW7) is a variable length symbology with an optional check digit and printable start/stop characters. Supported
characters include:
* Numeric digits 0 to 9
* special characters - $ : / , +
* start/stop characters are A, B, C or D
The checksum is calculated as the sum modulo 16 of the numerical values of all data characters.
String format:
start
char. data (1 or
more chars.) check
digit stop
char. CONTINUED ON NEXT PAGE...
Page 26