Opticon LGZ 7225 user manual Transmission

Models: LGZ 7225

1 87
Download 87 pages 63.7 Kb
Page 77
Image 77

Transmission

Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted.

Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted.

Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is “00” to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols; otherwise the insertion data is not effective.

Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted.

Program

 

Option Bar Code

 

Option

Alphanumeric

 

 

 

 

Entry

 

 

 

 

 

 

 

 

Disable

00

 

 

 

 

 

 

Enable

01

Preamble

 

 

 

transmission

 

 

 

 

 

 

 

 

 

 

 

Disable

00

 

 

 

 

 

 

Enable

01

Postamble

 

 

 

transmission

 

 

 

 

 

 

 

 

77

Page 77
Image 77
Opticon LGZ 7225 user manual Transmission