Opticon OPT-6125 user manual Setting the Number Characters to be Scanned

Models: OPT-6125

1 65
Download 65 pages 22.49 Kb
Page 17
Image 17

Manual No. 25-ULGPMU01-01

Series OPT Handheld

CCD Scanner

 

Setting the Number of

Characters to be Scanned

ZZ

Start/End

-[[-

 

ProgramMenu

 

H0

Fixed length

-I1-

 

OFF

Β

 

all codes

 

 

 

 

 

 

 

 

H1

Fixed length

-I2-

 

ON

 

 

all codes

 

 

 

 

 

 

HK

Fixed length

-IL-

 

ON

 

 

selected codes

 

 

 

 

 

 

HL

Min. length

-IM-

 

selected codes

 

 

 

 

 

HM

Max. length

-IN-

 

selected codes

 

 

 

 

 

Setting Code Specific Options - Options for specific codes may be configured affecting:

*Enabling and disabling code variants and translations.

*Data verification such as by mean of a check digit calculation. A check digit has a value that can be calculated from the other data characters and is usually the last data character in a bar code.

*Pre-editing of the data string such as removing the check digit and/or ST/SP characters.

The more common options are described here.

Check CD - Enables the check digit calculation. If the calculated check digit does not correspond to the check digit in the bar code, then the bar code is ignored. The use of a check digit greatly improves the security of a bar code. Do Not Check CD - Disables the check digit calculation. This option is required when the bar codes do not contain a check digit or contain an invalid check digit.

Transmit CD - Enables the transmission of the check digit together with the data characters. If the check digit calculation is disabled, the reader cannot differentiate anymore between a (valid) check digit and a data character. It will therefore transmit all data characters of the label, including what could constitute a check digit.

Do Not Transmit CD - Disables the transmission of the check digit. If the check digit calculation is disabled, the reader cannot differentiate between a (valid) check digit and a data character. It will therefore transmit all data characters of the able, excluding the character that could constitute the check digit for the type of bar code. Transmit ST/SP - Enables the transmission of the start and stop characters of a bar code.

Do Not Transmit ST/SP - Disables the transmission of the start and stop characters of a bar code.

Page 17

Page 17
Image 17
Opticon OPT-6125 user manual Setting the Number Characters to be Scanned